![Intel S2600IP Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/intel/s2600ip/s2600ip_technical-product-specification_2072184152.webp)
Appendix B: BMC Sensor Tables
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
138
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 4
Memory VRD
Hot 0-1
(P4 Mem01
VRD Hot)
9Ah
All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig
Offset
A
–
Processor 4
Memory VRD
Hot 2-3
(P4 Mem23
VRD Hot)
9Bh
All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig
Offset
A
–
Power Supply 1
Fan
Tachometer 1
(PS1 Fan Tach
1)
A0h
Chassis-
specific
Fan
04h
Generic
–
digital discrete
01
– State
Asserted
Non-fatal As and De
-
Trig
Offset
M
-
Power Supply 1
Fan
Tachometer 2
(PS1 Fan Tach
2)
A1h
Chassis-
specific
Fan
04h
Generic
–
digital discrete
01
– State
Asserted
Non-fatal As and De
-
Trig
Offset
M
-
Power Supply 2
Fan
Tachometer 1
(PS2 Fan Tach
1)
A4h
Chassis-
specific
Fan
04h
Generic
–
digital discrete
01
– State
Asserted
Non-fatal As and De
-
Trig
Offset
M
-
Power Supply 2
Fan
Tachometer 2
(PS2 Fan Tach
2)
A5h
Chassis-
specific
Fan
04h
Generic
–
digital discrete
01
– State
Asserted
Non-fatal As and De
-
Trig
Offset
M
-
Processor 1
DIMM
Aggregate
Thermal Margin
1
(P1 DIMM Thrm
Mrgn1)
B0h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
–
Содержание S2600IP