Appendix B: BMC Sensor Tables
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
136
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 2
DTS Thermal
Margin
(P2 DTS Therm
Mgn)
84h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 3
DTS Thermal
Margin
(P3 DTS Therm
Mgn)
85h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 4
DTS Thermal
Margin
(P4 DTS Therm
Mgn)
86h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor2
MSID Mismatch
(P2 MSID
Mismatch)
87h
All
Processor
07h
Digital Discrete
03h
01
– State
Asserted
fatal
As and De
–
Trig
Offset
M
–
Processor 1
VRD
Temperature
(
P1 VRD Hot
)
90h
All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig
Offset
M
–
Processor 2
VRD
Temperature
(
P2 VRD Hot
)
91h
All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig
Offset
M
–
Processor 3
VRD
Temperature
(P3 VRD Hot)
92h
All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Fatal
As and De
–
Trig
Offset
M
–
Содержание S2600IP