40
Intel® Server Board S1200BT Service Guide
[Enhanced] provides Native SATA support, using native SATA drivers included with the
vast majority of current operating systems.
[AHCI] enables the Advanced Host Controller Interface, which provides Enhanced SATA
functionality plus additional functionality such as Native Command Queuing. Uses AHCI
drivers available for the majority of current operating systems.
[RAID Mode] provides host based RAID support on the onboard SATA ports.
Comments:This option setting only appears when the SATA Controller is Enabled. In
order to use the AHCI setting, any OS being booted must have AHCI drivers available. If
the RAID Mode setting is chosen, then the following setting for RAID Mode Options will
appear.
Note:
When the SATA Mode setting is changed, before attempting to set the Boot Order it is
necessary to do a Save and Exit, and reboot to properly recognize any SATA hard drives.
3. RAID Mode Options
Option Values:
Intel
®
ESRT2 (LSI(TM))
Intel
®
RST (Matrix)
Help Text:
— Intel
®
ESRT2 (Powered By LSI(TM)): Supports RAID 0/1/10 and optional
RAID 5 with Intel
®
Embedded Server RAID Technology 2 (ESRT2). Uses
Intel
®
ESRT2 drivers (based on LSI(TM) MegaSR).
— Intel
®
RST (formerly known as Matrix RAID): Provides pass-through drive
support with Intel
®
Rapid Storage Technology(RST). Also provides host based
RAID 0/1/10/5 support. Uses Intel
®
RST iaStor drivers
Comments:This option setting only appears when the SATA Controller is enabled, and
RAID Mode has been selected as the operational SATA Mode. If a RAID Volume has not
previously been created, it will be necessary to Save and Exit and reboot in order to create
a RAID Volume.
4. Intel
®
Storage Module
Option Values:
None
<Name of Storage Module detected>
Help Text:Shows the name of the Storage Module detected, if one is installed.
Comments:Information only. If no Storage module is detected, then “None” is displayed.
— This shows the customer the product name of the module installed, which helps
in identifying drivers, support, documentation, etc by listing this on the BIOS
screen.
When an AXX4SASMOD Storage Module is detected, then (and only then) a following
option will be available for switching between IT/IR and ESRT2 RAID settings.
Содержание S1200BT
Страница 4: ...iv Intel Server Board S1200BT Service Guide 䞡㽕ᅝܼᣛᇐ ...
Страница 6: ...vi Intel Server Board S1200BT Service Guide ...
Страница 10: ...x Intel Server Board S1200BT Service Guide ...
Страница 16: ...xvi Intel Server Board S1200BT Service Guide ...
Страница 18: ...2 Intel Server Board S1200BT Service Guide Figure 2 Intel Server Board S1200BTS Picture ...
Страница 24: ...8 Intel Server Board S1200BT Service Guide ...
Страница 34: ...18 Intel Server Board S1200BT Service Guide ...
Страница 68: ...52 Intel Server Board S1200BT Service Guide Figure 23 System Information Screen S1200BTS ...
Страница 96: ...80 Intel Server Board S1200BT Service Guide ...
Страница 102: ...86 Intel Server Board S1200BT Service Guide ...
Страница 108: ...92 Intel Server Board S1200BT Service Guide ...
Страница 110: ...94 Intel Server Board S1200BT Service Guide ...
Страница 122: ...106 Intel Server Board S1200BT Service Guide ...