Intel® Server System R2000WF Product Family Technical Product Specification
72
Note
: Due to degraded performance and reliability concerns, the use of the 3.5” drive blank as a 2.5” drive
bracket is intended to support SSD type storage devices only. Installing a 2.5” hard disk drive into the 3.5”
drive blank cannot be supported.
Each drive carrier includes separate LED indicators for drive activity and drive status. Light pipes integrated
into the drive carrier assembly direct light emitted from LEDs mounted next to each drive connector on the
backplane to the drive carrier faceplate, making them visible from the front of the system.
Figure 46. Drive tray LED identification
Table 49. Drive status LED states
Amber
LED State
Drive Status
Off
No access and no fault
Solid on
Hard drive fault has occurred
1 Hz blinking
RAID rebuild in progress
2 Hz blinking
Locate (identify)
Table 50. Drive activity LED states
Green
Condition
Drive Type
LED Behavior
Power on with no drive activity
SAS/NVMe*
LED stays on
SATA
LED stays off
Power on with drive activity
SAS/NVMe*
LED blinks off when processing a command
SATA
LED blinks on when processing a command
Power on and drive spun down
SAS/NVMe*
LED stays off
SATA
LED stays off
Power on and drive spinning up
SAS/NVMe*
LED blinks
SATA
LED stays off
Table 51. PCIe* SSD drive status LED states
Amber
LED State
Drive Status
Off
No fault, OK
4 Hz blinking
Locate (identify)
Solid on
Fault/fail
1 Hz blinking
Rebuild
Amber status LED
Green activity LED
2.5” only
drive tray
Amber status LED
Green activity LED
2.5” / 3.5”
drive tray