Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
19
2.3
Air Duct Removal / Installation
Always operate your server chassis with the air duct in place. The air duct is required for proper airflow
within the server chassis.
2.3.1
Air Duct Installation
1.
Manage the system main power cable and CPU power cables under the notch of the air duct.
2.
Align the two tabs on the front edge of the air duct with the matching slots on the fan assembly.
3.
Lower the air duct into the chassis ensuring the two tabs are securely installed in the fan assembly.
2.3.2
Air Duct Removal
Lift the air duct straight up until the tabs on the front edge of the air duct are free from the fan
assembly.