![Intel P4304XXMFEN2 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/intel/p4304xxmfen2/p4304xxmfen2_service-manual_2071455100.webp)
Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
88
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h 4h 2h 1h 8h 4h 2h 1h
LED #
#7 #6 #5 #4 #3 #2 #1 #0
S3 Resume
E0h
1
1
1
0
0
0
0
0
S3 Resume PEIM (S3 started)
E1h
1
1
1
0
0
0
0
1
S3 Resume PEIM (S3 boot script)
E2h
1
1
1
0
0
0
1
0
S3 Resume PEIM (S3 Video Repost)
E3h
1
1
1
0
0
0
1
1
S3 Resume PEIM (S3 OS wake)
BIOS Recovery
F0h
1
1
1
1
0
0
0
0
PEIM which detected forced Recovery condition
F1h
1
1
1
1
0
0
0
1
PEIM which detected User Recovery condition
F2h
1
1
1
1
0
0
1
0
Recovery PEIM (Recovery started)
F3h
1
1
1
1
0
0
1
1
Recovery PEIM (Capsule found)
F4h
1
1
1
1
0
1
0
0
Recovery PEIM (Capsule loaded)