background image

5

General Installation Process

 

A

C

D

B

E

Other

Memory

DDR3

5

Install DIMM Memory Modules

To Install DIMMs:

DDR3L DIMM Memory Ide

ntification:

Open both DIMM socket levers.

C

A

D
E

Note location of alignment notch.

B

DIMM

notch and

socket

bump must

align as

shown.

This server board supports up to 4 DDR3L 1333/1600 ECC UDIMM. 

Non-ECC memory is NOT supported by this server board.

CAUTION:  

Observe normal ESD (ElectroStatic Discharge) procedures 

to avoid possible damage to system components.

Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.

Push down firmly on the DIMM until it snaps into place and both levers close.
IMPORTANT!  Visually check that each latch is fully closed 

and correctly engaged with each DIMM edge slot.

CAUTION: Avoid touching contacts when handling or installing DIMMs.

Install DIMM Memory Modules

... Continued

Intel

®

 Server Board 

S1200V3RPL

Note:

 For additional memory configurations, see the 

Service Guide

 on the 

Intel

®

 Server Deployment & Management DVD that accompanied 

your Intel

®

 Server System, or go to:  

http://www.intel.com/p/en_US/support/ 

(post-production)

Memory sizing and configuration is supported only for qualified DIMMs approved by 

Intel

®

. For a list of supported memory, go to: 

http://serverconfigurator.intel.com/sct_app.aspx 

(post-production)

For the best performance, a minimum of two DIMMs is recommended, populated 

in the blue slot of each memory channel.

DI

M

M

_A

2

DI

M

M

_A

1

DI

M

M

_B

2

DI

M

M

_B

1

CPU Socket

Содержание P4000RP

Страница 1: ...f you are not familiar with ESD Electrostatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other supporting docume...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...e 6 Install Hard Drive 6 Install PCI e Card Assembly 7 Install Intel Remote Management Module 4 NIC optional 7 Install RMM4 EMI Cover optional 8 Install Alternate Serial Port optional 8 Install Intel...

Страница 4: ...s subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2013 Intel Corporation All rights reserved Thermal Operation and Con g...

Страница 5: ...pply Two I O Ports A Kensington Cable Lock Mounting Hole PCI Add in Board Slot Covers AC Input Power Connector Two Alternate Serial Port Knockout RMM4 Knockout Padlock Loop Alternate RMM4 Knockout Act...

Страница 6: ...2 System Overview 0 1 2 3 4 5 6 7 Hot Swap Hard Drive Bay Options and HDD Numbering 8 x 3 5 Hot Swap Drive Cage A A...

Страница 7: ...s or install components B A A Remove the Side Cover B Remove the screws A NOTE A non skid surface or a stop behind the chassis may be needed to prevent the chassis from sliding on your work surface Sl...

Страница 8: ...e tip of the lever under the notch in the load plate Make sure the lever is securely latched CAUTION DO NOT damage the server board with the tip of the locking lever Save the protective cover A A A B...

Страница 9: ...e and both levers close IMPORTANT Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot CAUTION Avoid touching contacts when handling or installing DIMMs Instal...

Страница 10: ...plastic drive blank provided to maintain proper system cooling With the lever open insert the hard disk drive assembly into the cage opening and push until the locking lever engaged Push in the lever...

Страница 11: ...agement Module 4 NIC optional Top View A A Attach the metal fastening bracket to Intel Dedicated Server Management NIC module and secure the bracket with two screws B Remove the alternate RMM4 knock o...

Страница 12: ...is C secure the port with two screws D Connect the cable to the Serial B Connector on your server board CAUTION Carefully remove the knock out with screwdriver directly removing it with finger has pot...

Страница 13: ...pull out of the system by the handle NOTE Applies only to the chassis with hot swap power supply configuration A B A B CAUTION This chassis must be operated with the SIDE COVERS installed to ensure p...

Страница 14: ...nd Management DVD for update instructions B Con gure your RAID Controller Use the instructions provided with the RAID controller C Install your Operating System Use the instructions provided with the...

Страница 15: ...nector on backplane A Connect Mini SAS data cables B Connect two power cables C 8 x 3 5 HDD Cage NOTE Refer to the documents which come with your server board and or RAID controller card for instructi...

Страница 16: ...wer Front Panel SYS_FAN_1 SYS_FAN_4 Intel Integrated RAID Module SATA USB B D C E F A G J SAS SPGIO HSBP_I 2 C I PS AUX H K A CPU Power Cable B Server Board Main Power Cable C Backplane Power Cable D...

Страница 17: ......

Страница 18: ...G85600 002...

Отзывы: