background image

WARRANTY

Intek, Inc. warrants each Rheotherm product to be free from defects
in material and workmanship under normal use and service, Intek's
obligation under this warranty being limited to making good any part
or parts thereof which shall, within one (1) year after delivery of such
product to the original purchaser, be returned to Intek with
transportation charges prepaid and which Intek's examination shall
disclose to its satisfaction to have been thus defective; this warranty
being expressly in lieu of all other warranties, express or implied and
all other obligation or liabilities on Intek's part.  The purchaser will
assume all responsibility and expense for removal, decontamination
and reinstallation of equipment.

Rheotherm instruments are manufactured under United States patent numbers 4,255,968; 4,942,763, 4,949,578; 5,485,754; and 5,752,411; 

Intek, Rheotherm, RheoVac, Rheovec, Rheomax and RheoSmart are registered trademarks of Intek, Inc.

Intek, Inc.

751 Intek Way

Westerville, Ohio  43082-9057

TEL: (614) 895-0301  •  FAX: (614) 895-0319

website

www.intekflow.com

e-mail: [email protected]

Содержание Rheotherm 100CS

Страница 1: ...have been thus defective this warranty being expressly in lieu of all other warranties express or implied and all other obligation or liabilities on Intek s part The purchaser will assume all responsi...

Страница 2: ...START 7 3 2 SWITCH SETTINGS 7 3 3 GENERAL INFORMATION 7 3 4 USE AS A LEVEL SWITCH 7 SECTION 4 MAINTENANCE 8 4 1 GENERAL MAINTENANCE 8 4 2 SPARE PARTS 8 4 3 TROUBLE SHOOTING 9 TABLE I TROUBLE SHOOTING...

Страница 3: ...ndicating high and low flow conditions Key features of Rheotherm flow switches are Non intrusive flow monitoring For pipe sizes from 030 to inch flow sensing is done from outside the flow tube No movi...

Страница 4: ...ive transducer Example of Example of TU probe with probe with NPT fitting flange fitting 1 3 PRECAUTIONS 1 Use proper input power Check the label on the unit for the input power requirements 2 Use rea...

Страница 5: ...nstructionscoverinstallation operationandmaintenance ofRheothermflowswitches instandard configurations Any special information pertaining to your unit is covered under CUSTOM INFORMATION SECTION 6 Tim...

Страница 6: ...alling CAUTION The electronics box should never be rotated for any reason Straight run for a flow switch is not a requirement particularly for flow no flow indications but for best repeatability some...

Страница 7: ...el shall be properly grounded with an anti static device to prevent damage to components within the electrical enclosure The input power requirement is listed on the tag on the electronics enclosure m...

Страница 8: ...0 seconds and depends on where the trip adjust is set 2 4 ADJUSTING THE TRIP POINT Adjust the flow switch trip point as follows see Figure 2 for trip potentiometer location All adjustments must be mad...

Страница 9: ...O contact is open and LED color becomes red High Flow Switch The relay operation is exactly as described above When used as a high flow switch the alarm condition is considered to be when the relay i...

Страница 10: ...nts gas bubbles and non solubles can result in measurement below actual flow rates Periodic checks and cleaning should be performed to insure a clean pipe or probe surface It should be part of normal...

Страница 11: ...iometer clockwise until layer build up stabilizes After switch has been operating properly relay trips with flow above trip level and cannot be adjusted using SECTION 2 4 instructions Relay does not t...

Страница 12: ...ewed SECTION 4 3 TROUBLE SHOOTING and have questions please call our experienced engineers for assistance In many cases we can solve a problem over the phone Please provide as complete a description a...

Страница 13: ...CATION Model no Serial no Customer identification 6 2 CONFIGURATION The configuration of this unit as originally shipped from the factory Input Power 24 Vdc Line Connection 6 3 SPECIAL INSTRUCTIONS Re...

Страница 14: ...terface connector Enclosure lid 24 14 Ga Flow switch electronics Check enclosure label for proper input power For VDC input connect positive to H or terminal and negative to N or Figure 1 Model 100CS...