SECTION 5  

!

  CUSTOMER SERVICE

Intek's corporate philosophy is to solve our customer's difficult flow measurement/monitoring problems.
This means that each instrument is custom configured and calibrated for the application.  When you
purchase a Rheotherm instrument you also receive Intek's outstanding customer service.  For sales or
product service, call your local representative or Intek directly at (614) 895-0301 8AM to 5PM EST/EDT
weekdays or fax us anytime at (614) 895-0319.  Our customer service staff will provide assistance
promptly.  Our website at 

www.intekflow.com

 is available for additional information; for submitting

questions or comments, you may also e-mail to

 [email protected]

.

5.1 QUESTION ON EXISTING HARDWARE

To allow us to help you more quickly, please have the serial number of the equipment available before
you call.  If your company is not the original purchaser the identity of the original recipient will also be
helpful.

5.2 TROUBLE SHOOTING

If you have reviewed SECTION 4.3 TROUBLE SHOOTING and have questions, please call our
experienced engineers for assistance.  In many cases we can solve a problem over the phone.  Please
provide as complete a description as possible of the problems encountered.

5.3 FACTORY AND FIELD SERVICE

Model 100CS flow switches cannot be serviced in the field.  If a problem cannot be solved through a
telephone conversation with one of our engineers, the unit should be returned to the factory for
inspection.

To request factory service, a Return Material Authorization (RMA) and purchase order is required.  Our
customer service staff will assist you with the required information to return instruments for service.

5.4 DECONTAMINATION OF EQUIPMENT

For the safety of your personnel and ours, any hardware that has been in contact with potentially
hazardous liquids or gases must be properly decontaminated before shipment to Intek.

5.5 QUESTIONS ON NEW EQUIPMENT

For a new Rheotherm application or any liquid or gas flow measurement need, visit us at our website,

www.intekflow.com

 or contact your local Rheotherm representative or the Intek technical sales

department at the above phone/fax numbers.  Our staff will be pleased to answer all questions and
provide quotations.

Содержание Rheotherm 100CS

Страница 1: ...have been thus defective this warranty being expressly in lieu of all other warranties express or implied and all other obligation or liabilities on Intek s part The purchaser will assume all responsi...

Страница 2: ...START 7 3 2 SWITCH SETTINGS 7 3 3 GENERAL INFORMATION 7 3 4 USE AS A LEVEL SWITCH 7 SECTION 4 MAINTENANCE 8 4 1 GENERAL MAINTENANCE 8 4 2 SPARE PARTS 8 4 3 TROUBLE SHOOTING 9 TABLE I TROUBLE SHOOTING...

Страница 3: ...ndicating high and low flow conditions Key features of Rheotherm flow switches are Non intrusive flow monitoring For pipe sizes from 030 to inch flow sensing is done from outside the flow tube No movi...

Страница 4: ...ive transducer Example of Example of TU probe with probe with NPT fitting flange fitting 1 3 PRECAUTIONS 1 Use proper input power Check the label on the unit for the input power requirements 2 Use rea...

Страница 5: ...nstructionscoverinstallation operationandmaintenance ofRheothermflowswitches instandard configurations Any special information pertaining to your unit is covered under CUSTOM INFORMATION SECTION 6 Tim...

Страница 6: ...alling CAUTION The electronics box should never be rotated for any reason Straight run for a flow switch is not a requirement particularly for flow no flow indications but for best repeatability some...

Страница 7: ...el shall be properly grounded with an anti static device to prevent damage to components within the electrical enclosure The input power requirement is listed on the tag on the electronics enclosure m...

Страница 8: ...0 seconds and depends on where the trip adjust is set 2 4 ADJUSTING THE TRIP POINT Adjust the flow switch trip point as follows see Figure 2 for trip potentiometer location All adjustments must be mad...

Страница 9: ...O contact is open and LED color becomes red High Flow Switch The relay operation is exactly as described above When used as a high flow switch the alarm condition is considered to be when the relay i...

Страница 10: ...nts gas bubbles and non solubles can result in measurement below actual flow rates Periodic checks and cleaning should be performed to insure a clean pipe or probe surface It should be part of normal...

Страница 11: ...iometer clockwise until layer build up stabilizes After switch has been operating properly relay trips with flow above trip level and cannot be adjusted using SECTION 2 4 instructions Relay does not t...

Страница 12: ...ewed SECTION 4 3 TROUBLE SHOOTING and have questions please call our experienced engineers for assistance In many cases we can solve a problem over the phone Please provide as complete a description a...

Страница 13: ...CATION Model no Serial no Customer identification 6 2 CONFIGURATION The configuration of this unit as originally shipped from the factory Input Power 24 Vdc Line Connection 6 3 SPECIAL INSTRUCTIONS Re...

Страница 14: ...terface connector Enclosure lid 24 14 Ga Flow switch electronics Check enclosure label for proper input power For VDC input connect positive to H or terminal and negative to N or Figure 1 Model 100CS...

Отзывы: