Technical Data
5
Technical Data
5.1
Physical Features
All specified data was measured with nominal input voltage, at full load, and an am-
bient temperature of 25 °C. The limit value tolerances are subject to the usual varia-
tions.
Physical Feature
Value
Operating voltage
minimum 10 V DC
maximum 60 V DC
Power consumption idle
approx. 3 W
Power consumption connection
approx. 6.5 W
Level inputs
HIGH level = 3-12 V (contact open or
voltage strength for external supply)
LOW level = 0-1 V
Power consumption of an active input
against GND (internal 3.3 V)
Typically 0.5 mA (when enabling the
input by connecting to GND)
Switch output, maximum switch volt-
age
30 V (DC) / 42 V (AC)
Switch output, maximum current load 1 A (DC) / 0.5 A (AC)
Transmitted output:
EGSM 850 and 900: Class 4
EGSM 1800 and 1900: Class 1
EGSM 850 and 900: Class E2
GSM 1800 and 1900: Class E2
2 W
1 W
0.5 W
0.5 W
Weight
350 g
Dimensions (Width x Depth x Height)
70 mm x 110 mm x 75 mm
Temperature range
-20° C … 55° C
Maximum permissible humidity
95% non-condensing
IP rating
Housing IP40, Terminals IP20
Table 1: Physical Features