Technical Data
INSYS GPRS/EDGE 5.0 serial
98
12.3
Power Supply
All specified technical data was measured with a nominal input voltage, full load,
and an ambient temperature of 25.0 °C. The threshold value tolerances are sub-
ject to typical fluctuations. A maximum of one value may be operated in the
threshold value range.
The values were determined for a GSM receiving field strength of 16. For lower
field strengths on site, the values will increase, especially for CSD or GPRS/EDGE
data transmissions.
The current consumption during data transmissions may also increase if the an-
tenna is not adjusted correctly.
This can occur when:
The antenna and/or the antenna cable are not adjusted to 50
Ω
impedance.
The antenna that is being used is misaligned due to the situation at the instal-
lation site (metal parts …).
To operate the INSYS GPRS/EDGE 5.0 serial, a suitable device protection must be
used.
Power supply:
10.0.60 V DC
Current consumption - during normal operation -:
Supply Voltage
10V
24V
36V
Field strength
26
26
26
Standby
140
mA 60 mA
42 mA
CSD Data transmission
195
mA 84 mA
60 mA
GPRS/EDGE Data transmission
290
mA 84 mA
60 mA
Note:
Average values during data transmission and switched-on relay
(
AT**OUT1=close
,
AT**OUT2=close
).
Содержание EDGE 5.0 Series
Страница 1: ...Manual INSYS GPRS EDGE 5 0 serial Sep 10...
Страница 2: ......
Страница 63: ...INSYS GPRS EDGE 5 0 serial Functions 63...
Страница 67: ...INSYS GPRS EDGE 5 0 serial Functions 67 Configuration of the first device...
Страница 68: ...Functions INSYS GPRS EDGE 5 0 serial 68 Configuration of the second device...
Страница 103: ...INSYS GPRS EDGE 5 0 serial Declaration of Conformity 103 15 Declaration of Conformity...
Страница 104: ...Declaration of Conformity INSYS GPRS EDGE 5 0 serial 104...
Страница 107: ......