INSYS GPRS/EDGE 5.0 serial
Connection
41
5.3.4
Connection to Analogue Modems
Alternatively, the settings can be entered or modified using the terminal pro-
gram.
To call an analogue modem, an analogue
protocol must be set. While doing so it must
be observed that the remote terminal has to
work with the same protocol as well.
AT+CBST=<n>
The protocol V.32 with a data rate of 9600
baud.
AT+CBST=7
5.3.5
Connections to ISDN TAs
Alternatively, the settings can be entered or modified using the terminal pro-
gram.
To call an ISDN TA it is necessary to set the
ISDN protocol V.110. While doing so it must
be observed that the remote terminal has to
work with the same protocol as well.
AT+CBST=<n>
E.g.: The protocol V.110 with a data rate of
9600 baud.
AT+CBST=71
5.4
Direct GPRS/EDGE Connection via PPP
When the GPRS/EDGE functionality of the built-in GSM/GPRS/EDGE engine of the
INSYS GPRS/EDGE 5.0 serial is used directly, the INSYS GPRS/EDGE 5.0 serial pro-
vides only raw PPP data after dial-up into the GPRS/EDGE network. In this case,
the application must perform the required protocol stacks (PPP, TCP/IP) for the
application. In this mode, the TCP/IP stack of the INSYS GPRS/EDGE 5.0 serial is not
active.
Example: Connection via the RDT network of a PC.
The INSYS GPRS/EDGE 5.0 serial is the PPP server in this mode.
The direct utilization of GPRS/EDGE connections via PPP is not possible if the de-
vice is in active TCP Listen mode.
Содержание EDGE 5.0 Series
Страница 1: ...Manual INSYS GPRS EDGE 5 0 serial Sep 10...
Страница 2: ......
Страница 63: ...INSYS GPRS EDGE 5 0 serial Functions 63...
Страница 67: ...INSYS GPRS EDGE 5 0 serial Functions 67 Configuration of the first device...
Страница 68: ...Functions INSYS GPRS EDGE 5 0 serial 68 Configuration of the second device...
Страница 103: ...INSYS GPRS EDGE 5 0 serial Declaration of Conformity 103 15 Declaration of Conformity...
Страница 104: ...Declaration of Conformity INSYS GPRS EDGE 5 0 serial 104...
Страница 107: ......