![insys icom EBW-E100 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/insys-icom/ebw-e100/ebw-e100_manual_2070385079.webp)
EBW-E100
Functions
79
12.5.9
Configuring MCIP
MCIP (Management Control and Information Protocol) is a minimalist protocol for
exchanging short telegrams between an MCIP server and MCIP device drivers
based on TCP. Device drivers register with the MCIP server and inform it about the
Object IDs (OIDs) which can be addressed by it. An OID can be assigned to the
objects contained in the router so that they can be addressed in MCIP telegrams.
The state of the objects can be set and/or queried via the device drivers.
Configuration via web interface (menu "Server services", page "MCIP")
In order to enable device drivers to register with the MCIP server via
TCP, check the checkbox "Accept incoming TCP connections on port"
and specify the TCP port in the field behind.
In order to limit MCIP connections to the local network, check the
checkbox "Exclusively allow MCIP local". No MCIP connections will then
be accepted via the WAN interface.
Assign an Object ID to the objects contained in the EBW-E100 by
entering this into the field behind the respective object. An OID is a
number between 1001 and 65534.
Save your settings by clicking "OK".