APPENDIX A

SPECIFICATIONS

Voltage
Fuse

115 Vac, or 230 Vac, 50/60 Hz, 10
1/4 Amp. Fast Blow, 115 Vac./
1/8 Amp. Fast Blow, 23OVac.

Transducer Supply

12 Vdc, (unregulated) 250 mA Max.

Transducer Input:

Wave Shape
Types

Square, Sine

Maximum Input Frequency
Internal Pull-Up

Trigger Levels

Analog Output:

NPN Open Collector - PNP Open Collector -
Magnetic Pickup (Zero Crossing) - Logic Level

40 Khz - Master, 32 Khz - Follower
2.2 

 Pull-up to 12 V

2.5 Vdc NPN, PNP, and Logic Level
50 mV - Zero Crossing (100 mv Peak Minimum Signal)

Type
Maximum Output
Current
Resolution

Optically Isolated 0 to ±15 Vdc
Adjustable from ±3 Vdc to ±15 Vdc
10 mA Maximum
12-bit D/A Converter

Input Power:

External Control Inputs (Back Panel):

Sustained Contact Closures

Momentary Contact Closures.

Forward/Reverse

Closed Loop/Open Loop
Master/Follower
Keypad Unlocked/Keypad Locked

Set Points 1 & 3 / Set Points 2 & 4
Set Points 3 & 4 Enable
Local Command/Remote Command

Scroll Up/12 Scroll Down

External Start/Stop Switches (Back Panel):

Momentary, N.O. Run
Momentary, N.C. Stop
Momentary, N.O. Jog

Momentary, N.C. Emergency Stop

Back Panel Transistor Outputs:

NPN, open Collector Drivers
(50 Vdc Max, 250 mA
.3 Watts Max.)                       High Alarm

Low Alarm
Ramp Compete

Zero Speed
Deviation
Drive Enable

Operational Specifications:

Accuracy

Respons

Modes of Operation
Preset Speeds

Accel/Decel Times

Processor

Speed Display
Alphanumeric Display
Function LEDs

Diagnostics/2nd Function

Computer Interface

.01% of Speed Set Point (Master)

Zero Cumulative Error (Follower1

10-Millisecond Control Loop, Indivdually Adjustable
PID Gains

Master/Follower/Auxiliary Trim
4 Master, 4 Follower, 1 Jog
User Programmable from 0.1 to 600 Seconds
Intel 80C196TB 16-Bit Micro Controller

4-Digit, 7-Segment LED, .43-Inch height
8-Character, 5 x 7 Dot Matrix, .20-Inch height

1 Run (Green)
1 Stop (Red)
1 Local (Amber)
1 Remote (Amber)
1 Set Point 1 (Amber)
1 Set Point 2 (Amber)

Diag. 0 Custom User Unit Display
Diag. 1 Keypad Test
Diag. 2 Display Test

Diag. 3 Input Test
Diag. 4 Memory Test
Diag. 5 Output Test
Diag. 6 Serial Interface Test
Diag. 7 Return to Factory (Programming Defaults)

Diag. 8 Not Used
Diag. 9 Digital Speed Potentiometer

RS422 Interface Standard, 300 to 19200 Baud,
13 Character String, 1 Start, 8 Data, No Parity, 1 Stop

Mechanical/Environmental Specifications:

Enclosure Material
KeyPad

Cold Rolled Steel
Tactile Feedback Membrane, Chemical Resistant,

Operating Temperature

Splashproof

0°C to +50°C

Humidity
Panel Cutout

0 to 90%,Non-Condensing

Weight

5.4-inch Width x 2.7-inch Height x 7.20-inch Depth
6 lbs.

Specifications Subject to Change Without Notice

35

36

Содержание MicroSpeed 196

Страница 1: ...MSMAN32C MicroSpeed 196...

Страница 2: ...is designed in sequential order from basics to the highest level of MicroSpeed 196 programming The deeper you read into each section the less relevent the options may be to your application If this is...

Страница 3: ...d to the wiper of the speed potentiometer The isolated common terminal on the MicroSpeed 196 is connected to reference common on the drive Terminal locations are as follows TB2 2 Isolated Command Outp...

Страница 4: ...ignal from a PLC The MicroSpeed 196 only reads this input while stopped in the Ready mode Wiring of the Master Follower input is as follows TB1 15 Master Follower to common Open Master Closed Follower...

Страница 5: ...puts relays LEDs etc Power to the output circuits should be wired parallel with the Diode Protect TB2 20 terminal if inductive loads are driven to avoid damage to the output circuitry See Diagram 5 Wi...

Страница 6: ...display will prompt for a variable number and the numeric display will indicate two zeros 00 which will reflect the variable number entered Enter the desired variable number and press ENTER If you are...

Страница 7: ...FOLLOWER MODE The Microspeed 196 in the Follower mode mirrors a lead frequency input and can be scaled by the Ratio Set Point The lead frequency is typically generated from a digital transducer on ano...

Страница 8: ...can be independently locked The section of the keypad that is locked is determined by placing a 1 one in the appropriate location Any section or combination of sections can be locked See chart below...

Страница 9: ...ART MIN 56 PARTSIHR 57 Percent 58 RATIO 65 Customized 15 Diagnostic 0 Custom User Unit Labels If the choices presented in Variable 10 do not provide the display that is needed a Custom User Unit Label...

Страница 10: ...ect the proper polarity of the Command Output Voltage using the Forward Reverse Input Open Positive Closed Negative 3 Access Diagnostic 9 Digital Potentiometer by pressing 2nd Function key then the 9...

Страница 11: ...ters at the unstable speed 19 FOLLOWER MODE PID CONSIDERATIONS Variable 09 Max Lead Wind Up If you are speed matching and have very fast master speed changes or if you are bringing the Follower motor...

Страница 12: ...ill decrease motor speed Variable 28 Auxiliary Input Delay Delays the start of the Auxiliary Trim function on startup Enter the number of 10 msec update cycles to wait When ENTER is pressed the MicroS...

Страница 13: ...g inputs Closed Open Loop Master Follower Forward Reverse Keypad Unlocked Locked out Set Point 1 3 2 4 Set Point 3 4 Disabled Set Point 3 4 Enabled No Scroll Scroll Down No Scroll Scroll Up Left to ri...

Страница 14: ...oSpeed 196 with node address 01 will be the only MicroSpeed 196 to answer the host computer but all MicroSpeed 196 s will respond to global commands Never duplicate an address on the same communicatio...

Страница 15: ...ommunication Valid characters from the host are 0 command 1 read variable or 2 write variable The MicroSpeed 196 will echo the host in this character location unless the host communication message has...

Страница 16: ...in a message it will respond with a 3 in the Character 4 position The type of error will be specified in the Character 6 position Error type Problem 1 Parity Error Standard Definition 2 Data Error Da...

Страница 17: ...aximum Speed PPR Maximum Lead RPM Lead PPR User Unity Ratio Master Follower The active set point will only change with a Change Set Point command A write command to the active set point while running...

Страница 18: ...mp Compete Zero Speed Deviation Drive Enable Operational Specifications Accuracy Respons Modes of Operation Preset Speeds Accel Decel Times Processor Speed Display Alphanumeric Display Function LEDs D...

Страница 19: ......

Отзывы: