manualshive.com logo in svg
background image

RemoteLinc Owner’s Manual 

 

CREATING AN INSTEON SCENE 

INSTEON scenes let you activate dramatic lighting moods with the press of just one button. For example, 
you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with 
the tap of a button on a Controller. 

INSTEON scenes are very easy to set up – just Link more than one Responder to the same On/Off or 
Scene button on a Controller. Then, when you press any of the Linked buttons on the Controller, all of the 
INSTEON devices Linked in the scene will respond as a group. 

To set up an INSTEON scene, you can individually Link each device to a Controller. Or, save time and 
create multiple Links. See 

Multi-Linking and Multi-Unlinking. 

 

ADVANCED FEATURES  

Multi-Linking and Multi-Unlinking 

Multi-Linking 

Multi-Linking Mode allows you to Link multiple INSTEON devices to a single Controller and quickly create 
an INSTEON scene. Once the Controller is in Multi-Linking Mode, you can Link any number of 
Responders, one right after the other.  

The following will work for the most common INSTEON devices: 

1)  For each of the Responders you wish to control, set the device to the state you wish to activate from 

the Controller  

  If the Responder is a dimmable device, set the On-Level and Ramp Rate 

  If the Responder is a multi-scene device (e.g., another Keypad), tap the desired Scene button 

to illuminate the LED. (If you wish the Responder’s scene to turn off, tap the Scene button 
again to turn the LED off, and then proceed to the next step.) 

2)  Set the Controller to Linking Mode. (For most Controllers, press & hold the desired On or Scene 

button for 10 seconds or the Set button for 3 seconds.)  

3)  Tap the Set button on the Controller. If the Controller does not have a Set button, tap the same On or 

Scene button you used to put the Controller into Linking Mode. 

Multi-Linking Mode will automatically time out after 4 minutes of inactivity.   

4)  One at a time, press & hold each of the Responder’s Set buttons for 3 seconds

 

  

5)  After you have Linked all the desired Responders, tap the Controller’s Set button to exit Multi-Linking 

Mode. If the Controller does not have a Set button, tap the same On or Scene button you used to put 
the Controller into Linking Mode. 

6)  Test that the INSTEON scene is working as expected by tapping the button you just Linked to on the 

Controller  

Page 7 of 13 

Содержание SMARTHOME RemoteLinc 2440

Страница 1: ...RemoteLinc INSTEON Wireless Remote Control Model 2440...

Страница 2: ...ATING AN INSTEON SCENE 7 ADVANCED FEATURES 7 Multi Linking and Multi Unlinking 7 Enabling Disabling the Beeper 8 Enabling Disabling the Status LED 8 Stuck Button Feature 9 Restoring Power to RemoteLin...

Страница 3: ...AA batteries included and then Link to other devices in minutes Six individual On Off button pairs plus dedicated Dim Bright All On and All Off buttons Shows command transmission activity with a Statu...

Страница 4: ...es and then use a series of button presses or taps to Link your devices together Throughout this Owner s Manual you may see the terms Controller or Responder These generic INSTEON terms refer to the c...

Страница 5: ...ll adjust the brightness one of 32 steps for each tap Button Tap Press hold Bright Brighten a little Brighten until released Dim Dim a little Dim until released All On All Off Buttons The All On and A...

Страница 6: ...ould stop blinking and turn off BE CAREFUL Any accidental button presses will exit Linking Mode early 5 Confirm that Linking was successful by tapping the On Off buttons you just Linked to on RemoteLi...

Страница 7: ...EON devices 1 For each of the Responders you wish to control set the device to the state you wish to activate from the Controller If the Responder is a dimmable device set the On Level and Ramp Rate I...

Страница 8: ...e by tapping the buttons you just Unlinked from on the Controller Enabling Disabling the Beeper This procedure will toggle the RemoteLinc beeper on and off With the beeper turned off RemoteLinc will n...

Страница 9: ...he factory reset procedure will clear RemoteLinc of all INSTEON Links 1 If you are using RemoteLinc to control any INSTEON devices Unlink those devices from RemoteLinc See Unlinking an INSTEON Respond...

Страница 10: ...etransmit the command up to five times While using at least one dual band device is required when using an RF only device at least two dual band devices are recommended to ensure reliable communicatio...

Страница 11: ...sponder are being resent and loading down the signal If the above doesn t work perform a factory reset See Resetting RemoteLinc to its Factory Default Settings RemoteLinc can turn off my Responder but...

Страница 12: ...Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generat...

Страница 13: ...oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a partic...

Отзывы: