![Inspur TS860M5 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/inspur/ts860m5/ts860m5_user-manual_2069427067.webp)
61
BIOS Setup
Create RAID Menu Instruction Table
Interface Parameters
Function Description
Name
Please enter a volume label name less than 16 characters without containing any
special characters.
RAID Level
Please select RAID volume level. If no volume has been created at present, there are
four volume levels of RAID0 (Stripe), RAID1 (Mirror), RAID10 (RAID0+1) and RAID5
(Parity) for selection. Please select volume level according to actual requirements.
RAID0: This RAID volume is allowed to be made on 2 or above HDDs.
RAID1: This RAID volume is allowed to be made on 2 HDDs.
RAID10: This RAID volume is allowed to be made on 4 HDDs, which is only available
when HDD quantity is 4 or above.
RAID5 (Parity): This RAID volume is allowed to be made on 3 or above HDDs.
Select Disks
Select HDDs to make RAID volume, press Enter, select X, and then press Enter to
return to Create RAID Volume interface.
Strip Size
Please select the strip size, only RAID0 and RAID5 volumes could enable this option.
Capacity
Set the volume capacity.
2.3
Delete RAID Volume menu. After entering Delete RAID Volume menu, press [DEL] to
delete the selected RAID volume, and the system will prompt “ALL DATA IN THE VOLUME
WILL BE LOST! Are you sure you want to delete “Volume0*”? (Y/N)”. To delete this RAID
volume, please enter “Y”, to cancel the deletion, please enter “N”.
2.4
Reset Disks to Non-RAID menu. After entering Reset Disks to Non-RAID menu, system
will display all HDDs in RAID volume. Please use the space key to select the HDD to reset
according to the actual demand, and then press Enter to reset the HDD. The system will
prompt “Are you sure you want to reset RAID data on selected disks? (Y/N)” again, enter “Y”
or “N” according to the prompt. It is to be noted that all data on this disk will be lost after
reset. Meanwhile, this disk will not belong to RAID volume any more.
Содержание TS860M5
Страница 1: ...Inspur Server User Manual TS860M5 ...
Страница 40: ...34 CAUTION Please route the cables according to the purchased machine configuration ...
Страница 90: ...84 ...
Страница 94: ...88 9 7 BMC Settings Select BMC Settings on the navigation tree to open the BMC Settings interface It contains ...
Страница 96: ...90 ...
Страница 97: ...BMC Settings 91 ...
Страница 99: ...BMC Settings 93 ...
Страница 102: ...96 Restore factory defaults To restore BMC s configuration to factory state ...
Страница 103: ...BMC Settings 97 ...
Страница 104: ...98 ...