Description: The server is under normal operation, but the HDD status LED is off or red.
Suggestions:
a.
If it is caused by manual operations, restore the array through RAID configuration.
b.
If there is no manual operations, check whether the HDDs are identified normally. If the
server is configured with an RAID card, login to the RAID management interface to check
whether there is an HDD failure.
c.
If there is an HDD failure, or the above operations could not resolve the problem, please
contact Inspur customer service.
Note: Hot-plugging HDD allows users to take out or replace the HDD without system
shutdown and power off, which improves the system disaster recovery capability, scalability
and flexibility. It only means the hot-plug HDD can be plugged in and out online without
damage, and the following two items need to be noticed: ① Depending on the RAID level,
hot plugging the HDD in the RAID will cause RAID degradation or failure. When installing
a new HDD, different RAID cards have different policies, you may need to login to the
RAID card management interface for recovery. ② Remove the HDD until the HDD motor
stops completely, to prevent damage to the motor. For the operations on the RAID card
management interface, please refer to Inspur technical website:
6) Chassis fans make excessive noise
Suggestions:
a.
Firstly check whether the chassis fans operate at a high speed caused by the over-
temperature chassis.
b.
If the chassis has a high temperature, check the temperature of server room, if it is
excessively high, open the air conditioner to cool the room.
c.
If the server room’s temperature is normal, check whether the front panel or chassis
interior is jammed with dust, or the air inlet is blocked. It needs to improve the server
room’s environment, to avoid server over-temperature running because of too much dust.
d.
Check whether the server runs under high load.
e.
If above operations could not resolve the problem, please contact Inspur customer
service.
Содержание TS860M5
Страница 1: ...Inspur Server User Manual TS860M5 ...
Страница 40: ...34 CAUTION Please route the cables according to the purchased machine configuration ...
Страница 90: ...84 ...
Страница 94: ...88 9 7 BMC Settings Select BMC Settings on the navigation tree to open the BMC Settings interface It contains ...
Страница 96: ...90 ...
Страница 97: ...BMC Settings 91 ...
Страница 99: ...BMC Settings 93 ...
Страница 102: ...96 Restore factory defaults To restore BMC s configuration to factory state ...
Страница 103: ...BMC Settings 97 ...
Страница 104: ...98 ...