69
Configuration
Max.
Operating
Temperat
ure at 30°C
Max.
Operating
Temperature
at 35°C
Max.
Operating
Temperature
at 40°C
Max.
Operating
Temperature
at 45°C
consumption)
with GPUs
Passive-cooli
ng DIMMs
(including
BPS) higher
than 8 W not
supported
TDP higher
than 165 W
not
supported
DIMMs
(including
BPS) higher
than 6 W not
supported
12 × 3.5-inch
NVMe drives
All
configurations
(When GPUs
are equipped,
there are
restrictions on
drive numbers
and CPU
power
consumption)
8 or less
drives and
CPUs with
TDP at 205 W
or lower
supported
when
equipped
with GPUs
DIMMs
(including
BPS) higher
than 8 W not
supported
Passive-cooli
ng GPUs not
supported
CPUs with
TDP higher
than 205 W
not
supported
DIMMs
(including
BPS) higher
than 8 W
not
supported
Passive-cooli
ng GPUs not
supported
Rear drives
not
supported
CPUs with
TDP higher
than 165 W
not
supported
DIMMs
(including
BPS) higher
than 6 W not
supported
24 × 2.5-inch
pass-through
drives
24 × 2.5-inch
NVMe drives
8.8
Operational Requirement
This section specifies the requirements of temperature, humidity, organisms,
chemical materials and mechanically active materials in the server room when the
server is operating.
1.
Temperature and humidity
The temperature, dew point and relative humidity in the server room should meet