![Inspur NF5260FM6 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/inspur/nf5260fm6/nf5260fm6_user-manual_2069392049.webp)
41
information. If the power module LED is abnormal, see Situation 1: Power
Module LED Not Lit or Turning Red in the No Power Upon Boot section for
reference.
c.
If other LEDs are abnormal, log in to the BMC Web GUI to check whether
there is an alarm. If yes, record the specific alarm information.
d.
If none of the preceding operations can resolve the problem, call Global
Service Hotline 1-844-860-0011 (toll-free)/1-760-769-1847 (DID) or email
us at
to inform the specific alarm and problem.
8.1.4
Stuck on Self-test or Other Screens Upon Boot
Description:
After the power button was pressed, the server failed to boot properly but was
stuck on the self-test or other screens.
Handling suggestion:
a.
If the server is stuck on the Media Test Failure screen, check if the server
has installed OS successfully and set the OS boot option to the first in
order.
b.
If the screen that the server is stuck on contains hardware error message
such as memory and RAID controller card self-test error, take note of the
error message.
c.
If the server is stuck on the self-test screen, which reports an error, take
note of the error message.
d.
If none of the preceding operations can resolve the problem, call Global
Service Hotline 1-844-860-0011 (toll-free)/1-760-769-1847 (DID) or email
us at
to inform the error message.
8.1.5
Power Module LED Not Lit or Turning Red
Description:
When the server was powered up using the power module, the device was running
properly, but a power module LED on the rear window was not lit or turned red.
Handling suggestion:
a.
Check if the external power supply environment is powered on and if the
server appearance is burnt or vulcanized.
b.
Check whether the power cable of the server is properly plugged, and re-
plug the power cable.
c.
If the problem still exists, power off and reseat the power module.
Содержание NF5260FM6
Страница 1: ...Inspur Server NF5260FM6 User Manual Document Version V1 0 Release Date 2021 05 28 ...
Страница 27: ...19 Item 2 Top PCIe0 1 2 Slot Bottom OCP 3 0 NIC 3 Drive Bay 9 4 PSU ...
Страница 32: ...24 Figure 4 4 Removing the air director ...
Страница 44: ...36 Figure 5 16 Installing the fan module 4 Repeat steps 2 3 to install the remaining fan modules ...