33
Expansion Card Components
To avoid damage to the server or expansion card, power off the server and
remove all AC power plugs before removing or installing the PCIe riser
assembly.
For proper cooling, do not run the server without the server top cover, air
directors, expansion slot covers, or blanks installed. If the server supports
hot-swap of components, avoid frequently opening the top cover of the
server.
1.
Power off the server.
2.
Pull the server out of the rack.
3.
Remove the server top cover.
4.
Remove the PCIe riser assembly as shown in the figure below.
Figure 5-10 Removing the PCIe riser assembly
5.
Loosen the fastening screws and open the PCIe card latch.
Figure 5-11 Opening the latch