Hardware Components
Introduction
Do not touch the drive and internal system components before they cool down
to prevent injuries caused by overheating on the server surface.
To prevent damage to electronic components, properly ground the server before
starting any installation steps. Improper grounding may cause electrostatic
discharge.
To install multiple components, read the installation instructions for all hardware
components and identify similar steps to simplify the installation process.
Processor Components
To avoid damage to processors and mainboard, only authorized operators
can replace and install the processors on the server. Do not install the
processor without using the processor installation tool.
To prevent server failure or damage, make sure that the processors used in
a multi-processor configuration must have the same component ID.
To install a processor with a high speed, update the system ROM before
installing the processor.
To install the component:
1.
Power off the server.
2.
Pull the server out of the rack.
3.
Remove the server top cover.
4.
Remove the air director.