23
Parameter
Description
Read Policy
Read policy of virtual drives, including:
No Read Ahead
: Read Ahead disabled.
Read Ahead
: Read Ahead enabled. The controller can
read sequential data ahead or predict data to be used
and cache it.
Write Policy
Write policy of virtual drives.
Write Back
: When the controller has no BBU (Battery
Backup Unit), the BBU is charging/discharging or
damaged, or the pinned/preserved cache reaches 50%
of the physical cache capacity of the RAID controller
card, the RAID controller card automatically switches to
the
Write Through
mode. This mode is the
recommended standard mode.
Write Through
: After the disk subsystem receives all
data transmitted, the controller returns a data
transmission completion signal to the server.
Always Write Back
: After the cache of the controller
receives all data transmitted, the controller returns a
data transmission completion signal to the server.
Note:
In
Always Write Back
mode, if the super-capacitor is absent
or in the charging state, the written data in DDR memory of
the RAID controller card will be lost. This mode is not
recommended.
I/O Policy
I/O policy of virtual drives for specific virtual drive read
scenarios, which does not affect cache of Read Ahead. Only
the
Direct
mode is available to 94xx series or later controller
cards.
Direct
: In read scenarios, data is directly read from
drives. (except for the case where
Read Policy
is set to
Read Ahead
, in which case read data is cached on the
RAID controller card.)
In write scenarios, written data is cached on the RAID
controller card. (except for the case where Write Policy is
set to Write Through, in which case data is directly
written into drives without being cached on the RAID
controller card.)
Содержание 3408 Series
Страница 62: ...57 Figure 3 52 Selecting the Drive to be Configured Figure 3 53 Operation Screen ...
Страница 68: ...63 Figure 3 59 Operation Screen 3 Delete the HS drive a Set Operation to Unassign Hot Spare Drive ...
Страница 78: ...73 Figure 3 73 Setting Choose Profile to 13_PD64 NVMe4 ...
Страница 83: ...78 Figure 4 6 Checking I Accept the License Terms 9 Select Custom advanced and press Enter as shown below ...
Страница 84: ...79 Figure 4 7 Selecting Custom advanced 10 On the screen shown select Load Driver and press Enter ...
Страница 85: ...80 Figure 4 8 Selecting Load Driver 11 On the screen shown click Browse and press Enter ...
Страница 86: ...81 Figure 4 9 Clicking Browse To install the driver 1 Select GHOST C as shown below ...
Страница 89: ...84 Figure 4 12 Loading the Driver 4 On the screen shown click Next ...
Страница 91: ...86 Figure 4 14 Selecting a System Partition 6 Click OK to enter the OS installation screen as shown below ...
Страница 93: ...88 Figure 4 16 Installing Windows 8 Create an administrator password and press Enter to enter the OS ...