REMEMBER:
These showers are designed to be free standing and movable
from their location should you have need to replace anything. AL-
WAYS USE Flexible braided water inlet pipes at least a metre long
(not central heating plastic type! ) from
house supply to the shower and again flexible waste pipe to join
to your house waste. NEVER fix with rigid pipes, never fix the unit
to the wall.
DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE.
ALWAYS FIT "EASY TO GET TO TAP VALVES" ON BOTH HOT AND COLD WA-
TER. THE SAME AS A DISHWASHER OR WASHING MACHINE THIS PRODUCT
SHOULD BE ISOLATED WHEN NOT IN USE
NOTE:
From time to time these showers may have small differ-
ences from that of these instructions. Due to continuous improve-
ments and upgrades, this should not cause you any inconvenience
just sometimes extra commonsense needs applying as changes
1.
2 People
2.
Scissors
3.
Silicone Gun
4.
Knife
5.
Tape Measure
6.
Spirit Level
7.
Phillips Screwdriver
8.
Drill
YOU WILL NEED
TOTAL ELECTRICAL REQUIREMENTS
Voltage Rating 220 -240AC
Frequency Rating 50HZ
Power Rating 3.0KW
Other than steam generator
Internal Circuit Voltage is 12V
Internal Current Rating 0.17A
Your electrical contractor should understand ALL legal require-
ments of connection before undertaking any work or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!!
Note for electrician. This product comes with 13 amp plug(s) fitted
with RCD unit. We leave the way you prefer to connect this to your-
self due to continued additions to current regulations. As at October
2010 we offered two following alternatives.
1) Connect within current laws and IP directives using plug and RCD
provided with steam version or supply one for non steam version
2) (Preferred) Wire into isolated fused feed connecting directly to
the house consumer / service box. Remove the plug / RCD fitted and
ensure the Consumer unit has capabilities to replace RCD feature.
Always use protection against electrical surge. Your shower should
be treated the same as a home computer. A surge protector should
eradicate the possibility of either the transformer or computer con-
trol being burnt out because of this reason.
Please note earth is required and found on chassis of shower tray. A
further earth is required from Steam Generator unit. Each earth
must ground through power supply line.