22
F0-15 Start mode
0: Direct start
1: Rotation velocity search restart
1
0
×
15
F0-16 Stop mode
0: Deceleration stop
1: Coast to stop
1
0
○
16
F1 Motor Parameter
F1-00 Motor type selection
0: Common asynchronous motor
1: variable frequency asynchronous motor
2: Permanent magnetic synchronous
motor (Reserved)
1
0
×
17
F1-01 Rated power
0.1kW ~ 1000.0kW
0.1
Depending
on inverter
model
×
18
F1-02 Rated voltage
0V ~ 440V
1
Depending
on inverter
model
×
19
F1-03 Rated current
0.00A ~ 655.00A
0.01
Depending
on inverter
model
×
20
F1-04 Rated frequency
0.0Hz ~ 3200.0Hz
1
50.0Hz
×
21
F1-05 Rated speed
0rpm ~ 30000rpm
1
1460
×
22
F1-06 Stator resistance
0.001
Ω
~ 65.535
Ω
0.001
Ω
Depending
on inverter
model
○
23
F1-07 Rotor resistance
0.001
Ω
~ 65.535
Ω
0.001
Ω
Depending
on inverter
model
○
24
F1-08 Leakage inductance
0.01 ~ 655.35mH
0.01mH
Depending
on inverter
model
○
25
F1-09 Mutual inductance
0.1mH ~ 6553.5mH
0.1mH
Depending
on inverter
model
○
26
F1-10 Excitation current
0.01A ~ 655.35A
0.01A
Depending
on inverter
model
○
27
F1-11 Tuning selection
0: No tuning
1: Static tuning
2: Complete tuning
1
0
×
28
F2 Vector and VF Control Parameter