Err 37
Err37
Brake contactor
feedback
abnormal
101: The output of the brake
contactor is inconsistent with the
feedback.
102: When both feedback signals of
the brake contactor are enabled, their
states are inconsistent.
103: The output of the brake
contactor is inconsistent with the
feedback 2.
104: When both feedback 2 signals of
the brake contactor are enabled, their
states are inconsistent.
101, 104:
Check whether the brake coil and
feedback contact are correct.
Check the signal feature (NO, NC) of
the feedback contact.
Check whether the control circuit of
the brake contactor coil is normal.
5A
Err 38
Err38
Encoder signal
abnormal
101: Pulse signal change in F4-03
does not change within the time
threshold in of F1-13.
102: The running direction and pulse
direction are inconsistent.
101, 102 :
Check whether the encoder is used
correctly. Exchange phases A and B
of the encoder.
Check whether the system and signal
cables are grounded reliably.
Check whether cabling between the
encoder and the PG card is correct.
5A
Err 39
Err39
Motor overheat
101: The motor overheat relay input
remains valid for a certain time.
101:
Check whether the thermal protection
relay is normal.
Check whether the motor is used
properly and whether it is damaged.
Improve cooling conditions of the
motor.
3A
Err 40
Err40
Elevator running
reached
The set elevator running time is
reached.
Check the related parameter, or
contact the agent or Monarch.
4B
Err 41
Err41
Safety circuit
disconnected
101: The safety circuit signal
becomes OFF.
101:
Check the safety circuit switches and
their states.
Check whether the external power
supply is normal.
Check whether the safety circuit
contactor acts properly. Confirm the
signal feature (NO, NC) of the
feedback contact of the safety circuit
contactor.
5A
Err 42
Err42
Door lock
disconnected
during running
101: The door lock circuit feedback is
invalid during the elevator running.
101:
Check whether the hall door lock and
the car door lock are in good contact.
Check whether the door lock
contactor acts properly.
Check the signal feature (NO, NC) of
the feedback contact on the door lock
contactor.
Check whether the external power
supply is normal.
5A
Err 43
Err43
Up limit signal
abnormal
101: The up limit switch acts when
the elevator is running in the up
direction.
101:
Check the signal feature (NO, NC) of
the up limit switch.
Check whether the up limit switch is
in good contact.
Check whether the limit switch is
installed at a relatively low position
4C