NICE Series Integrated Elevator Solution 

 N Quick Start-Up Guide V1.0               

 

 

 

Sr No 

Subject 

Page 

Safety Information and Precautions 

Product Information 

1  Connection of peripheral electrical Devices 

2  System configuration of N 

3  Designation Rules and Nameplate 

4  Models, Power, Current Rating and DBR requirements 

5  Physical Appearance and Mounting Dimensions 

6  Mechanical Installation 

7  NICE Power terminal & MCTC-MCB-G Main Control Board Details 

10 

8  Description of the MCTC-KZ-D Extension Card 

12 

9  Selection and Use of the MCTC-PG Card 

14 

Elevator Hoistway Switches and Sensor Installation  

17 

1  Terminal floor switches mounting position 

17 

2   Installation of levelling Plate/Flag and Switches 

18 

Complete Electrical configuration of N all Field Interface 

20 

Initial Start-up Commissioning 

21 

1   Identify the NICE 1000 control Panel components 

21 

2  Verification of Controller and Field wiring 

21 

3  Check list for N Initial Power Up 

22 

4  Remote MDKE LED Keypad function 

23 

5  Input and Output functional sequence of  Main Control Board (MCTC-MCB-H) of NICE 1000+ 

24 

6  Input terminal LED Sequence for Main Control Board (MCB) while Initial start-Up 

25 

7  N Start-up Parameterisation 

26 

8  Commissioning at Inspection Speed 

27 

9  Inspection Running 

30 

Normal/High Speed Operation 

31 

1  Elevator Shaft Learning Process 

31 

2  Door operator commissioning 

32 

3  Normal Operation & Its Signal Verification 

34 

4  Floor Level Adjustment 

35 

5  Car & Landing Calls configuration 

35 

6  Floor display Setting 

36 

7  Rescue function using UPS ready on power failure 

37 

8  Load Weigh Function 

38 

9  Ride Comfort Fine Tuning 

39 

Function Code Table 

40 

1  Meaning of each column in Function Code Table 

40 

2  Function Code Group 

40 

3  Function Code in details 

40 

Fault Information and Troubleshooting 

72 

1  Description of Fault Information 

72 

2  Fault Levels 

72 

3  Fault Information and Troubleshooting 

73 

 
 

Содержание NICE1000+

Страница 1: ...CE 1000 control Panel components 21 2 Verification of Controller and Field wiring 21 3 Check list for NICE1000 Initial Power Up 22 4 Remote MDKE LED Keypad function 23 5 Input and Output functional se...

Страница 2: ...only by qualified personnel under instructions described in suitable electrical wiring diagram and user manual Ensure that the cabling satisfies the EMC requirements and local codes Use wire sizes rec...

Страница 3: ...es the service life of the controller Select a proper breaker to resist large in rush current that flows into the controller at power on Use within the allowable power supply specification of the cont...

Страница 4: ...grated Elevator Solution NICE1000 Quick Start Up Guide V1 0 4 2 2 System configuration of NICE1000 The NICE1000 Integrated Elevator Control Solution combines the functions of both Elevator control and...

Страница 5: ...Frequency V F control Start up torque 0 5 Hz 180 SVC 0 Hz 200 CLVC Speed adjustment range 1 100 SVC 1 1000 CLVC 1 50 V F Speed stability accuracy 0 5 SVC 0 05 CLVC Torque control accuracy 5 CLVC Overl...

Страница 6: ...on Status monitor Monitoring the state of feedback signals to ensure that the elevator works properly I O feature Digital input DI 24 x DI Input specification 24 V 5 mA 3 higher voltage detection inpu...

Страница 7: ...L H H1 2003 5 9 17 0 14 0 3 7 54 50 1100 220 NICE L H H1 4007 7 0 20 5 18 0 4 0 40 35 1200 220 NICE L H H1 4011 10 0 29 0 27 0 5 5 29 25 1600 220 NICE L H H1 4015 12 6 36 0 33 0 7 5 26 22 2500 220 NIC...

Страница 8: ...34 5 347 223 143 6 5 5 5 NICE L H 2003 220 NICE L H 4007 150 334 5 347 223 173 5 6 5 7 220 NICE L H 4011 220 NICE L H 4015 220 NICE L H 4018 195 335 350 210 192 6 9 1 220 NICE L H 4022 220 NICE L H 40...

Страница 9: ...easily cause dust adhesion and further a fault on the drive unit A vent must be available at bottom of the control cabinet to form bottom up air flow which prevents heat island effect on the surface...

Страница 10: ...nect the DC reactor do not remove the jumper bar U V W Controller Output Power Terminal Connect to the three phase Hoist Motor PE Grounding Terminal Must be connected with Earth Ground Bus bar 2 7 2 D...

Страница 11: ...nt limit 5 mA Functions set in F5 01 to F5 24 AI M AI AI Used for the analog load cell device CN7 X25 to X27 XCM Higher voltage detection terminal Input voltage range 110 VAC 15 110 VDC 20 for safety...

Страница 12: ...ential monitoring CN12 RJ45 interface Interface for operation panel Used to connect the operation panel J12 Interface for connecting the PG card J9 J10 Factory reserved Do not short them randomly Othe...

Страница 13: ...cator output 24 V power for button illumination CN1 YM Y4 Y5 Y2 3 to Y27 Relay output Normally open NO maximum current and voltage rating 5 A 250 VAC Function set in F7 03 to F7 27 CN2 Interface for c...

Страница 14: ...of the MCTC PG card Directly insert the J1 terminal of the MCTC PG card into the J12 terminal of the controller 2 9 1 Appearance of the MCTC PG card and its installation on the controller 2 9 2 Selec...

Страница 15: ...TOMATION NICE Series Integrated Elevator Solution NICE1000 Quick Start Up Guide V1 0 15 Absolute encoder ECN413 1313 MCTC PG F1 2 9 3 Details on Different Encoders wiring configuration with different...

Страница 16: ...INOVA AUTOMATION NICE Series Integrated Elevator Solution NICE1000 Quick Start Up Guide V1 0 16...

Страница 17: ...slow down distance V indicates the F0 04 Rated elevator speed and F3 08 indicates the special deceleration rate The default value of F3 08 Special deceleration rate is 0 5 m s2 The slow down distance...

Страница 18: ...0 supports below three combinations of Door Zone and Up Down levelling sensor switches for elevator floor stopping at floor level Third method of having Up Down levelling switches and Door Zone switch...

Страница 19: ...INOVA AUTOMATION NICE Series Integrated Elevator Solution NICE1000 Quick Start Up Guide V1 0 20 4 Complete Electrical configuration of NICE1000 all Field Interfaces...

Страница 20: ...g are proper and well tightened at controller Check all Field Wiring Machine Room Controller Hoist way Car top COP and LOP are connected as per the suitable Electrical Drawing Check control panel wiri...

Страница 21: ...5 3 4 Turn ON the NICE1000 Control Panel Circuit Breakers one by one and check the voltage level simultaneously Make sure that the voltage levels are within specified limits Refer Electrical Drawing 5...

Страница 22: ...dicator ON running OFF stop LED display for parameters Program key Menu mode selection key Run key Multi function selection key Stop Reset key Shift key Increment key Decrement key Confirm key Paramet...

Страница 23: ...hase P of 110VAC power supply for enabling and disabling the safety circuit function These 110VAC voltage safety points X25 X27 are first and most priority inputs in the NICE1000 Lift controller Err41...

Страница 24: ...l X9 ON F5 09 115 NC UP and Down Limit and Slow down Switches must be connected for Inspection run and for motor tuning Down direction limit signal X10 ON F5 10 116 NC Up terminal slowdown signal X11...

Страница 25: ...Synchronous Motor Gearless Rated Voltage V F1 02 Rated Current I F1 03 Rated Frequency F F1 04 Rated Speed RPM F1 05 Motor Type Selection F1 25 0 Asynchronous 1 Synchronous Encoder Parameter Details...

Страница 26: ...ine Brake applied condition On Load Rotational tuning N A F1 11 1 Tuning takes place during Inspection mode Up Down running with load on machine No load Rotational Tuning F1 11 2 F1 11 2 No Load on Ma...

Страница 27: ...to start on load pole tuning Select F1 11 2 Remote keypad shows tUNE press RUN key to start the Rotational auto tuning Remove load from the machine Keep open the machine brake for rotor free movement...

Страница 28: ...tting and wiring 5 8 4 Error in tuning process Error Code Fault Details Remedies Err20 Encoder Fault Check the Encoder Parameter F1 00 0 F1 12 2048 Check the Motor name plate parameter Thoroughly chec...

Страница 29: ...ches are wired up and located in the right position as given in the manual Use the UP and DOWN Button in the Inspection board on controller Car Top to run the lift in Inspection speed Check the direct...

Страница 30: ...d field wiring are completed Take the lift to bottom terminal floor level using control panel Inspection in inspection speed Observe the X1 X24 input terminal LEDs for proper operation of Floor Door z...

Страница 31: ...learning refer the Error history for remedies and re do the shaft tuning 6 2 Door operator commissioning 6 2 1 Auto door DOL and DCL NO type feedback status on MCB of NICE1000 for different door posi...

Страница 32: ...er Sequence can lead to Err53 If DOL is not detected even after door protection time gives Err55 Landing Door Safety Car Door Safety X26 OFF X27 OFF X26 OFF X27 OFF X26 ON X27 ON Door Open Command Y6...

Страница 33: ...Mode Inspection mode UP signal X5 OFF F5 05 010 NO For UP direction command in INS mode Inspection mode DOWN signal X6 OFF F5 06 011 NO For DOWN direction command in INS mode UP direction limit signal...

Страница 34: ...inal L1 L26 of MCB can be programmed in F6 11 F6 36 using Keypad In NICE1000 Call functions are programmable and the default NICE1000 unit is programmed for 5 floor full collective call function For b...

Страница 35: ...r Down landing Call F6 32 252 Default L22 2nd Floor Down landing Call F6 33 253 Default L23 3rd Floor Down landing Call F6 34 254 Default L24 4th Floor Down landing Call F6 35 255 Default L25 5th Floo...

Страница 36: ...06 Hb 0 b3 0 b2 1 b1 1 b0 0 For FE 12 0101 Hb 1 b3 0 b2 0 b1 0 b0 1 Grey Display output For FE 02 1902 Hb 0 b3 0 b2 0 b1 1 b0 1 For FE 03 1903 Hb 0 b3 0 b2 0 b1 1 b0 0 For FE 15 0105 Hb 1 b3 1 b2 0 b1...

Страница 37: ...sed on Analog Load weigh 2 Automatic pre torque compensation 0 Keep F8 01 2 if no load weigh system is used Load Weigh Type Selection F8 08 0 Digital Type Load weigh 1 Reserved 2 Analog Type Load Weig...

Страница 38: ...loop gain using following parameters Description Code Default Remarks Proportional gain 1 of Speed Loop Kp1 F2 00 40 Increase or Decrease to improve Smooth start Integrate time 1 of Speed Loop Ki1 F2...

Страница 39: ...of all parameters to prevent mal function 7 2 Function Code Group F0 Basic parameters F9 Time parameters F1 Motor parameters FA Keypad setting parameters F2 Vector control parameters Fb Door function...

Страница 40: ...n 1 With load auto tuning 2 No load auto tuning 3 Shaft auto tuning 1 4 Shaft auto tuning 2 5 Static auto tuning 0 F1 12 Encoder PPR 0 10000 1024 PPR F1 13 Encoder signal detection time 0 10 0 1 0 s F...

Страница 41: ...eleration start jerk time 0 300 4 000 2 500 S F3 04 Acceleration end jerk time 0 300 4 000 2 500 S F3 05 Deceleration rate 0 200 0 800 0 300 m s2 F3 06 Deceleration end jerk time 0 300 4 000 2 500 S F...

Страница 42: ...igh byte of floor height 5 0 65535 0 Pulses F4 15 Low byte of floor height 5 0 65535 0 Pulses F4 16 High byte of floor height 6 0 65535 0 Pulses F4 17 Low byte of floor height 6 0 65535 0 Pulses F4 18...

Страница 43: ...023 Door 2 open limit signal 024 Door 1 close limit signal 025 Door 2 close limit signal 026 Door 1 light curtain signal 027 Door 2 light curtain signal 028 Attendant signal 029 Non Stop signal in att...

Страница 44: ...play 1 The keyboard tube order is 5 4 3 2 1 from left to right Every passage s definition is as follows Digit Sequence Segment Function 1 A Reserved B Up Levelling signal active C Down Leveling signal...

Страница 45: ...it 2 signal active G Half load signal active DP Reserved F5 29 I O terminal status display 2 Digit Sequence Segment Function 1 A Reserved B Safety circuit signal active C Door lock circuit 1 signal ac...

Страница 46: ...ve B Door 1 close button input and output active C Door 1 open delaying button input and output active D Car call of door 1 on the 1st floor input and output active E Car call of door 1 on the 2nd flo...

Страница 47: ...input and output active 5 A Up call of door 1 on the 9th floor input and output active B Down call of door 1 on the 9th floor input and output active C Reserved D Down call of door 1 on the 10th floor...

Страница 48: ...Down call of door 2 on the 5th floor input and output active C Up call of door 2 on the 6th floor input and output active D Down call of door 2 on the 6th floor input and output active E Up call of d...

Страница 49: ...nction control 1 0 65535 Bit0 Reserved Bit1 Returning to base floor if position deviation too large Bit2 Reserved Bit3 Buzzer not tweet upon re levelling Bit4 Reserved Bit5 Cancelling auto reset of do...

Страница 50: ...ion button 205 210 Reserved 211 226 Door 1 Car call 227 230 Reserved 231 245 Door 1 up hall call 246 251 Reserved 252 266 Door 1 down hall call 267 299 Reserved 201 Door 1 door opening button 202 Door...

Страница 51: ...Function 301 303 Door 1 switch the door 304 Door 2 selection button indicator 305 310 Reserved 311 326 Door 1 Car call 327 330 Reserved 331 345 Door 1 up hall call 346 351 Reserved 352 366 Door 1 dow...

Страница 52: ...verse floor number clear Bit10 Reserved Bit11 Responding to car calls first then hall calls Bit12 Reserved Bit13 Reserved Bit14 Reserved Bit15 Reserved 00000 b00 0 b01 0 b02 0 b03 0 b04 0 b05 0 b06 0...

Страница 53: ...0 b15 0 F6 67 Attendant function selection 0 65535 Bit0 Calls cancelled after entering attendant state for the first time Bit1 Not responding to hall calls Hall call blinks inside the car call button...

Страница 54: ...on Bit15 Automatic door open in fire emergency floor 00000 b00 0 b01 0 b02 0 b03 0 b04 0 b05 0 b06 0 b07 0 b08 0 b09 0 b10 0 b11 0 b12 0 b13 0 b14 0 b15 0 F6 69 Emergency evacuation function selection...

Страница 55: ...tion selection of shorting stator braking mode to become the setting of related function effective F6 70 Reserved F6 71 Reserved F6 72 Emergency evacuation switching speed 0 010 0 630 0 010 m s F6 73...

Страница 56: ...h 7 segment b display output 43 High 7 segment c display output 44 High 7 segment d display output 45 High 7 segment e display output 46 High 7 segment f display output 47 High 7 segment g display out...

Страница 57: ...oor for an idle elevator 0 240 10 Min F9 01 Fan Light turn off time 1 240 0 Fan and lamp always ON 2 Min F9 02 Max floor running interval 0 45 Invalid if smaller than 3s 45 s F9 03 Accumulative workin...

Страница 58: ...Door close 4 Door close limit 5 Running Bit 4 Bit 5 Bit 6 Bit 7 Elevator state 0 Inspection 1 Shaft auto tuning 3 Return to base floor at fire emergency 4 Fire fighter operation 6 Attendant operation...

Страница 59: ...ommand Bit 9 Door 2 Close command Bit 10 Low 7 segment a display output Bit 11 Low 7 segment b display output Bit 12 Low 7 segment c display output Bit 13 Low 7 segment d display output Bit 14 Low 7 s...

Страница 60: ...The LEDs are arranged as 5 4 3 2 1 from left to right LED 1 shows the state of door 1 LEDs 2 and 3 have no display LEDs 4 and 5 together show the elevator state The following figure shows the elevator...

Страница 61: ...s of the 16 functions in this parameter in addition to LED s 5 4 3 informations The above indication shows display of FA 26 LEDs 5 4 and 3 show that function 10 Inspection down is 1 Valid LEDs 1 and 2...

Страница 62: ...5 0 Reserved 8 Reserved 1 Higher voltage safety circuit 9 Reserved 2 Higher voltage door lock circuit 1 10 Reserved 3 Higher voltage door lock circuit 2 11 Reserved 4 Reserved 12 Reserved 5 Reserved 1...

Страница 63: ...or 12 Car call 4 Floor 5 Car call 12 Floor 13 Car call 5 Floor 6 Car call 13 Floor 14 Car call 6 Floor 7 Car call 14 Floor 15 Car call 7 Floor 8 Car call 15 Floor 16 Car call FA 36 Floor I O state 3 D...

Страница 64: ...half load 13 6 System light load 14 7 15 FB Door Function Parameter Fb 00 Number of door machines 1 2 1 Fb 01 Opposite door options 0 3 0 Simultaneous control for both Door 1 2 1 Hall call independent...

Страница 65: ...r 16 of Door Machine 2 65535 b00 1 b01 1 b02 1 b03 1 b04 1 b05 1 b06 1 b07 1 b08 1 b09 1 b10 1 b11 1 b12 1 b13 1 b14 1 b15 1 Fb 05 Delay at stop after re levelling 0 00 2 00 0 00 s s Fb 06 Door open p...

Страница 66: ...t 3 Reserved Bit 4 Light curtain judgement at door close limit Bit 5 Cancelling SPI communication judgement Bit 6 to Bit 8 Reserved Bit 9 Cancelling Err55 alarm Bit 10 to Bit 13 Reserved Bit 14 Cancel...

Страница 67: ...code 0 9999 0 FC 29 7th Fault sub code 0 65535 0 FC 30 8th Fault code 0 9999 0 FC 31 8th Fault sub code 0 65535 0 FC 32 9th Fault code 0 9999 0 FC 33 9th Fault sub code 0 65535 0 FC 34 10th Fault code...

Страница 68: ...05 display 5 06 display 6 07 display 7 08 display 8 09 display 9 10 display 10 11 display b 12 display G 13 display H 14 display L 15 display n 16 display P 17 Reserved 18 display _ 19 no display 23 D...

Страница 69: ...Reserved Bit7 Reserved Bit8 Reserved Bit9 Reserved Bit10 NO NC output selection of shorting PMSM stator contactor Bit11 Reserved Bit12 Fan Lamp output Bit13 to Bit 15 Reserved 00000 b00 0 b01 0 b02 0...

Страница 70: ...on selection Bit1 Semi auto door function mode1 Bit2 Semi auto door function mode2 Bit3 Disable DOL DCL function Bit4 Indian Fireman operation selection Bit5 Buzzer intermediate for manual door open B...

Страница 71: ...ration rate and cannot restart 3B In low speed running the elevator does not stop In normal speed running the elevator stops and then can start running at low speed after a delay of 3s Level 4 1 Displ...

Страница 72: ...oller output short circuit 5 Check whether motor parameters comply with the nameplate 6 Perform motor auto tuning again 7 Check whether the brake keeps released before the fault occurs and whether the...

Страница 73: ...inate external power supply faults and check whether the power fails during running 2 Check whether the wiring of all power input cables is reliable 3 Contact the agent or Monarch 5A Err 10 E10 System...

Страница 74: ...rotate properly 2 The motor auto tuning times out 3 The encoder for the PMSM fails 1 Enter the motor parameters correctly 2 Check the motor wiring and whether phase loss occurs on the contactor at th...

Страница 75: ...Err26 Err26 Earthquake signal 101 The earthquake signal is active and the duration exceeds 2s 101 Check that the earthquake signal is consistent with the parameter setting NC NO of the MCB 3B Err 29...

Страница 76: ...nning 111 115 The stored floor height is smaller than 50 cm 112 The floor when auto tuning is completed is not the top floor 113 The pulse check is abnormal 101 Check that the down slow down switch is...

Страница 77: ...s valid for a certain time 101 Check whether the thermal protection relay is normal Check whether the motor is used properly and whether it is damaged Improve cooling conditions of the motor 3A Err 40...

Страница 78: ...alid and there is shorting door lock circuit feedback 104 During re levelling no shorting door lock circuit feedback or door lock signal is received 2s after shorting door lock circuit output 101 Chec...

Страница 79: ...nal is valid 102 Check whether when the hall door lock signal and the car door lock signal are detected separately the detected states of the hall door locks and car door lock are inconsistent 5A Err5...

Страница 80: ...E1000 Quick Start Up Guide V1 0 81 Err62 Err62 Analog input cable broken The Analog input cable of the CTB or the MCB is broken 101 Check whether F8 08 is set correctly Check whether the Analog input...

Отзывы: