Acceleration / deceleration time:
terminal 1
The selection of the 4 acceleration/deceleration can be
chosen by ON/OFF.
For more details, look at the
table 2
17
Acceleration / deceleration time:
terminal 2
18
Tilt of the frequency pilotage
Allows switching between different pilotage modes of the
frequency. The terminal is used to commute between two
frequency mode, depening on the selection of the
frequency source parameter (F0.07)
19
Up/Down setting
When the reference frequency is digital, this terminal is
used to erase the frequency value modified by the
terminal UP/DOWN, in such a way that reference
frequency can recover the instruction value (F0.01)
20
Terminal block control communication
When the control is set on the terminal block (F0.11=1),
the terminal can be used to commute between the
terminal block control and the keyboard control. When
the control is set on the control communication (F0.11=2),
the terminal can be used to switch between the control by
Modbus communication and keyboard control
21
Acceleration / deceleration
prohibited
Make sure that the inverter is free of internal signals. This
function maintain the current output frequency
22
Break of the PID regulation
The PID regulation is temporally desactivated, the inverter
maintain the actual output frequency.
23
Reset of the controller
When the controller stops and starts again, this terminal is
used to reset the inverter.
24
Rebalancing break
When the inverter will give in output the half of the
frequency, the rebalancing will be in break.
25
Counter input
Impulsion input terminal of counting
26
Reset of the meter
Erase the actual value of the counter
27
Counting input of the length
Input terminal of the length of counting
28
Reset length
Erase the actual value of the length
29
Torque control prohibited
When the torque control is prohibited, the inverter switch
in speed control mode.
30
High speed pulse input
(only for DI5)
DI5 is used as pulse inputs terminals.
31
Reserve
32
Immediate release of the DC brake
If the input is activated, the inerverter switch to braking
stage DC.
33
External defect, input closed
When the external defect signal is put in the inverter, the
inverter reports this signal and stops.
34
Validation of the frequency switch
If the input is activated, and if the frequency instructiong
changes, the inverter doesn’t react to these frequency
modifications until the input is no longer activated.