15
d.
Input settings
Code
Designation
Range
Factory value
Modification
when the
motor is ON
F1.00
Input terminal
block DI1
0 to 50
1
No
F1.01
Input terminal
block DI2
0 to 50
2
F1.02
Input terminal
block DI3
0 to 50
8
F1.03
Input terminal
block DI4
0 to 50
9
F1.04
Input terminal
block DI5
0 to 50
12
F1.05
Input terminal
block DI6
0 to 50
13
F1.06
Input terminal
block DI7
0 to 50
0
F1.07
Input terminal
block DI8
0 to 50
Setting
value
Function
Description
0
No function
No action of the inverter
1
Direction of rotation forward( FWD)
Choice of direction of rotation
2
Direction of rotation reverse(REV)
3
Control mode 3 electric wires
For more details look at the instructions of the functions
code F1.10
4
Mode : JOG Forward
Control in JOG mode
5
Mode: JOG Reverse
6
Frequency increase
Change the frequency of the increment/decrement
control when the digital setting is selected as the
frequency control (F0.03=0 or 1)
7
Frequency decrease
8
Stop "Freewheel"
The motor stops on his own.
9
Reset of a defect
To restore an inverter defect
10
Break is functionning
The inverter stops but all the parameters are stored, as
the acceleration/deceleration and instruction frequency.
When the break is over, the inverter restarts.
11
External defect : input open
When the signal is sent to the inverter, it refers to the
Err.15, and it makes the repair according to the chosen
protection action on F8.17
12
Multi-speed : terminal 1
The speed setting can be done by 16 settings predefined
and controlled through 4 input terminals. For more
details
,
look at the
table 1.
13
Multi-speed : terminal 2
14
Multi-speed : terminal 3
15
Multi-speed : terminal 4