- Machine  should  be  protected  under  perfect

working  condition  and ensured  that  is  operates

under the operator’s safe working conditions.

Rules  listed  below  should  especially  be

observed

:

- This machine should only be used in accordance

with  the  main  purposes  it  was  designed  for.  Any

other usage is dangerous and inconvenient.

- Protect  the  machine  from  atmospheric  events
(rain, direct sun rays, etc.).
- Do  not  let  children  and  unauthorized  and
untrained personnel operate the machine.
- The  machine  should  only  be  operated  by
authorized and trained personnel.
-

Keep  the  machine  in  perfect  operation

conditions,  do  not  use  different  protection
equipment,  and  be  careful  about  operating
security  equipment.  Periodical  maintenance
should be performed by a trained technician.
- Make sure electricity and water connections are
proper before connecting the machine.
- Make  sure  that  the  machine  is  grounded  in
compliance with legal regulations. Compliance of
the  machine  should  be  controlled  by  trained
personnel.
- Make  sure  that  the  electricity  system  is
sufficient  for  the  maximum  power  drawn  by  the
machine.
- Cables  between  the  electrical  system  and  the
main switch should comply with the instructions.
Do  not  dismantle  the  cables  without  checking  if
they have power or not.
- A  H07RN-F type  feeding  cable  should  be  used
for this machine.
- The  machine  should  be  disconnected  from  the
electricity  system  by  turning  the  main  switch  off
before any maintenance work.
- When a malfunction occurs in the machine, turn
the machine off from the main switch and do not
try 

to 

repair 

the 

machine 

under 

any

circumstances.

-

Repair  work  should  only  be  done  by

manufacturing  company  or  authorized  technical
service with original spare parts.
- Do  not  use  water  to  extinguish  a  fire broke out
in  electrical  components.  Use  powder  based  fire
extinguishers.
- Do  not  change  the  protections.  Lift  them  when
the machine is turned off or its power is cut off.
- If  the  machine  will  not  be  used  again,  cut  the
power off and remove the power cable.
- Read  the  instructions  in  the  user’s  guide  for
cleaning the machine.
- Do not clog the suction part.
- Do not turn the machine on without a filter.
- Only  authorized  technicians  should  open  the
control panel.
- Do  not  put  your  hands  in  detergent  water.  In
case  of  contact  with  your  eyes,  rinse  with  plenty
of water.
- Do not open the door too fast. Open the door 15
seconds after the motor stopped.
- When  the  door  is  open,  make  sure  the  support
pillar holds the door.
- If the security switch stops the conveyor system,
remove the material that caused the switch to stop
the system before restarting the machine.
- Make  sure  the  plate  sizes  comply  with  the
machine sizes.
- Do not use any dispensary or equipment that are
not  used  by  the  manufacturer  company.
Otherwise,  working  order  the  machine  may  be
altered and security issues may arise.
- Use  non-foam  detergents.  Use  the  detergent  in
the  amounts  suggested  by  the  manufacturer
company  according  to  the  hardness  of  water  and
tank capacity.
- Do  not  use  acid  or  corrosive  substances  for
washing the plates or cleaning the machine.
- Do  not  use  sharp  objects  like  stainless  brushes
while cleaning the stainless pillar.
- Not  using  corrosive  and  environmentally
harmful  substances  or  exceed  the  suggested
amounts to protect the environment.
- Personnel  handling  the  plates post-wash  should
comply with legal hygiene regulations.

Содержание BKE2000L

Страница 1: ...UZU TR USER S MANUAL EN 2000Tabak saat KURUTMA T NELL KONVEY RL 2000 Plate hour DRYING TUNNEL CONVEYOR BULA IK YIKAMA MAK NASI DISHWASHING MACHINE MODEL BKE2000L BKE2000R Revizyon No 00 Y r rl l k Tar...

Страница 2: ...2...

Страница 3: ...plam Elektrik Kapasitesi Total electricity capacity kW 31 Elektrik Giri i Total electricity capacity V 380 400V 3N AC 50 60Hz Kablo Kesiti Cable section mm2 4x16 10 Net A rl k Net weight Kg 450 L Sol...

Страница 4: ...k vb bula klar zel olarak tasarlanm kasalar i erisinde y kamak i in dizayn edilmi tir Cihaz s rekli bu i i in tahsis edilmi kalifiye bir eleman taraf ndan kullan lmal d r yi bir y kama kalitesi i in...

Страница 5: ...500 C civar nda su girece i dikkate al narak belirlenmi tir So uk su giri lerinde boyler ve tank s t c lar n n al ma ortam na g re boyutland r lmas yap l r Kurutma Makinan n istenilen standartlarda i...

Страница 6: ...ajlar Plastik poli retan malzeme tahta ivi vb tehlikeli oldu u i in ocuklar n ula amayaca yerlere konulmal d r 9 2 Makinenin pozisyonu genel kurulumuna uyum g stermeli Zemin d z ve d emesi makinenin a...

Страница 7: ...ye yandaki gibi ba lay n d1 Pano zerindeki kapa y ld z u lu tornavida yard m ile c vatalar n saat y n tersine evirerek kar n d2 Paslanmaz kapa panonun yan taraf na kald r n d3 Bara kutusu zerindeki PV...

Страница 8: ...ebeke suyunda a r bir mineral yo unlu u var ise makinenin su giri inden nce mineral z c bir sistem montaj yap lmal d r B ylece su sertli i a a daki tabloda belirtilen de erler aras na d ecektir Tablo...

Страница 9: ...anseri 25 ve 24 nolu terminallere direkt olarak ba lamay n ve ba lant y uygun r le kullanarak yap n b Y zey aktif dispanserin tesisat Y kama tank n n yan nda durulama b l m n n alt ndaki delik deterja...

Страница 10: ...ana gelen yang n s nd rmek i in su kullanmay n z onun yerine toz i erikli yang n s nd rmeleri kullan n z Korumalar de i tirmeyin yaln zca makine al mazken yada enerjisi kesili iken kald r n Makine bir...

Страница 11: ...ipman tan nm olacakt r 13 2 BAKIM G VENL K KURALLARI Her bak m i lemi g venlik kurallar dahilinde ger ekle melidir Kumanda panelinin i inde g venli al mak i in elektrik kesicisinde i bitti inde elektr...

Страница 12: ...achine should be performed in accordance with the manufacturer company s relevant instructions by someone experienced in this regard Electrical and water connections of the machine should be done acco...

Страница 13: ...rbage bin skin counter and outlet counter may be installed on the device to create an integrated dishwashing system Use liquid and non lathery detergent for washing Amounts of detergent and rinse aids...

Страница 14: ...g environment in cold water inlets Drying In order to ensure the drying stage meets all required standards Hard water should not be used in washing and rinsing stages Hard water leads to spots on drie...

Страница 15: ...urethane materials woods nails etc are dangerous and should be kept away from children 9 2 Position of the machine should be compatible with general installation Foundation should be flat and tiling s...

Страница 16: ...Connect the power source cable to the machine as shown in the image d1 Remove the screw on the panel with the help of a fillister head screw driver d2 Lift the stainless lid near the panel d3 Lift the...

Страница 17: ...er inlet This way water hardness will fall down to the values shown in the table below Table 2 Connect the water inlet pipe located under the machine to a hot water pipe or a cold water pipe if the ma...

Страница 18: ...sing WARNING Do not directly connect the dispensary to terminals 25 and 24 and use a suitable relay for connection b Installation of the surface active dispensary The hole under the rinsing section be...

Страница 19: ...any circumstances Repair work should only be done by manufacturing company or authorized technical service with original spare parts Do not use water to extinguish a fire broke out in electrical compo...

Страница 20: ...13 2 MAINTENANCE SAFETY RULES Each and every maintenance work should comply with safety rules To ensure safe work in the control panel cut the electricity off from electricity flow wall by turning it...

Страница 21: ...d clean the filter Choose a longer washing period or repeat the same period 2 Dishes are broken Improper basket is used Machine is overloaded Pay attention to basket preference Comply with the machine...

Страница 22: ...22 BKE 2000L R ELEKTR K EMASI ELECTRICAL SCHEDULE BKE 2000L R ELECTRICAL SCHEDULE...

Отзывы: