11.6
Low Power Mode Timing Diagram
Low power Mode can be used with all none serial communication protocols to reduce
the power consumption of the N when idle. When the N is in
this state the current consumption is reduced. The N goes into low power
mode approximately 6 seconds after the validator is powered up and remains in this
state until a note is entered (Time A, Figure 10). Following a note insertion, the
N returns to Low Power mode approximately 1 second after the Busy line
goes High (After credit is given or note is rejected). (Time B, Figure 10).
When the Validator is enabled the Inhibit line is Low and the Busy line is High. This
remains the same until a note is inserted (Time A). When a note is inserted under
the front sensor the N wakes up and the busy line goes low to indicate
that the validator is in use. The busy line remains low during the validating and
stacking process and once the note has been successfully validated and stacked the
vend line goes low to issue the credit. After the credit is issued the busy line goes
high and approximately 1 second after the busy line goes high (Time B) the
N goes back into low power mode.