NV10 FAMILY USER MANUAL
Copyright © Innovative Technology Ltd 2016
Doc: GA02116 - NV10 FAMILY USER MANUAL
Version:1.1
Page 21 of 80
Once the files are loaded onto the DA3 the Validator can be updated. For this a
ribbon cable needs to be connected between the validator port on the DA3 and the
validator. The host machine cable connected to the spare port on the DA3 as shown
below:
Once the unit is connected, ensure it is in SSP, press the play button in the middle,
the DA3 will begin to download. If there is an issue t
he ‘BNV Match Download’ LED
will begin to flash.
Should an error occur whilst updating the unit via the DA3, a flash code will be
displayed on the DA3 Mode LED indicator as shown below:
1 Long flash
followed by
–
Number of SHORT flashes
Indicated Status / Error
2
No validator connection found
3
No valid download files found
4
Download fail
5
Memory card fail
5.4.3
SMART Update
Smart update is a utility which bundles up a regions dataset into one file. No settings
will be altered during the update only the dataset and firmware.
All the details of DA3 using can be found in the