42
9. Troubleshooting
9.1 Indoor unit error display
For 7k,9k, 12k, 16k, 17k,18k models:
Operation lamp Timer lamp
Failure
X
Indoor fan speed has been out of control
O
The T1 or T2 sensor is open circuit or short circuit
X
Over current protection occurs 4 times.(except
MSR1-07HR-NB4(A),
MSR1-09HR-NB4(A),
MSR1-12CR-NB4 2T0032500152)
O
EEPROM error
Zero crossing detection error
For MSR1-09HRN1-NB8 and MSR1-12HRN1-NB8 models:
Display
LED STATUS
E1
EEPROM error
E2
Zero crossing detection error
E3
Indoor fan speed has been out of control
E4
Over current protection of the compressor occurs 4 times
E5
Open circuit or short circuit of indoor room temperature sensor
E6
Evaporator temperature sensor open circuit or short circuit
For 21k,24k,
ELBR-KFR70G/N1Y-R1R15(B8)-W models:
Operatio
n lamp
Timer
lamp
Defrosting
lamp(only for
heat pump
models)
Auto
lamp
Failure
Over current protection occurs 4 times.
X
X
X
The T2 sensor is open circuit or short circuit
X
X
X
The T1 sensor is open circuit or short circuit
Содержание Oasis WOE10C2DB1 / HOE10C2MR83
Страница 10: ...8 Model W H D WOE10C2DB8 710 250 189 WOE13C2DB8 790 275 196 WOE18C2DB8 930 275 198 WOE24C2DB8 1036 315 230 ...
Страница 14: ...12 5 Wiring Diagram 5 1 Indoor Units WOE10C2DB8 WOE13C2DB8 WOE18C2DB8 WOE24C2DB8 ...
Страница 15: ...13 5 2 Outdoor Units HOE10C2MR83 HOE13C2MR83 HOE18C2MR83 ...
Страница 16: ...14 HOE24C2MR83 ...
Страница 46: ...44 9 2 Diagnosis and Solution 9 2 1 Indoor fan speed has been out of control diagnosis and solution ...
Страница 48: ...46 9 2 2 Open circuit or short circuit of temperature sensor diagnosis and solution ...
Страница 49: ...47 9 2 3 Over current protection occurs 4 times diagnosis and solution ...
Страница 51: ...49 9 2 6 Indoor outdoor units communication error diagnosis and solution ...