Step 6: neaten the pipes
1
. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10 cm.
2
. If the outdoor unit is higher than the wall hole,
you must set a U-shaped curve in the pipe
before pipe goes into the room, in order to
prevent rain from getting into the room.
wall
U-shaped curve
drain hose
Installation of outdoor unit
2
. Fix the power connection wire and signal control wire with wire clip
(only for cooling and heating unit).
Note:
• After tighten the screw, pull the power cord slightly to check if it is firm.
• Never cut the power connection wire to prolong or shorten the distance.