Requirements for electric connection
Safety precaution
1.
Must follow the electric safety regulations when installing the unit.
2.
According to local saftey regulations, use qualified power supply circuit and air switch.
3.
Make sure the power supply matches with the requirement of air conditioner. Unstable power
supply or incorrect wiring or malfunction. Please install proper power supply cables before using
the air conditioner.
4.
Properly connect the live wire, neutral wire and grounding wire of power socket.
5.
Be sure to cut off the power supply before proceeding any work related to electricity and safety.
For models with a power plug, make sure the plug is within reach after installation.
6.
Do not put through the power before finishing installation.
7.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similary qualified person in order to avoid hazard.
8.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
9.
The appliance shall be installed in accordance with national wiring regulations.
10.
Appliance shall be installed, operated and stored in a room with a floor area larger than “X”m
2
(see table a).
Please notice that the unit is filled with flammable gas R32. Inappropriate treatment
of the unit involves the risk of severe damages of people and material. Details to this
refrigerant are found in chapter “refrigerant”.
Grounding requirement
1.
The air conditioner is the first class electric appliance. It must be properly grounding with
specialized grounding device by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
2.
The yellow-green wire in air conditioner is grounding wire, which can’t be used for other
purposes.
3.
The grounding resistance should comply with national electric safety regulations.
4.
The appliance must be positioned so that the plug is accessible.
5.
An all-pole disconnection switch having a contact separation of at least 3 mm in all poles should
be connected in fixed wiring.
6.
Including an air switch with suitable capacity, please note the following table. Air switch should
be included magnet buckle and heating buckle function, it can protect the circuit-short and
overload. (Caution: please do not use the fuse only for protect the circuit)
Air-conditioner
Circuit break capacity
09K
10A
12K
16A
18K
16A