ENG
28
09
18
12K :
24K :
Installation of outdoor unit
Step 4: connect indoor and outdoor pipes
1
. Remove the screw on the right handle of
outdoor unit and then remove the handle.
1
. Remove the wire clip; connect the power connection wire and signal control wire (only for
cooling and heating unit) to the wiring terminal according to the color; fix them with screws.
3
. Pretightening the union nut with hand.
2
. Remove the screw cap of valve and aim the
pipe joint at the bellmouth of pipe.
4
. Tighten the union nut with torque wrench
by referring to the sheet below.
Step 5: connect outdoor electric wire
screw
handle
liquid
valve
liquid pipe
pipe joint
union nut
gas pipe
gas valve
Hex nut diameter
Tightening torque
(N.m)
Ø 6
15~20
Ø 9.52
30~40
Ø 12
45~55
Ø 16
60~65
Ø 19
70~75
Note:
the wiring board is for reference only, please refer to the actual one.
09
18
12K :
24K :
indoor unit connection
indoor unit connection
POWER
POWER
N(1)
N(1)
N
N
N
L
L
2
2
L
3
3
N
L
yellow-
green
yellow-
green
yellow-
green
yellow-
green
brown
brown
black
black
brown
(black)
brown
(black)
blue
blue
blue
blue
18K