ENG
27
Installation of outdoor unit
Step 1: fix the sopport of outdoor unit
(select it according to the actual installation situation)
1
. Select installation location according to the house structure.
2
. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
• Take sufficient potective measures when installing
the outdoor unit.
• Make sure the support can withstand at least four
times of the unit weight.
• The outdoor unit should be installed at least 3 cm
above the floor in order to install drain joint.
• For the unit with cooling capcity of 2300W~5000W,
6 expansion screws are needed; for the unit with
cooling capacity of 6000W~8000W, 8 expansion
screws are needed; for the unit with cooling capacity
of 10000W~16000W, 10 expansion screws are
needed.
Step 2: install drain joint
(Only for cooling and heating
unit)
1.
Connect the outdoor drain joint into the hole
on the chassis, as shown in the picture below.
2.
Connect the drain hose into the drain vent.
Step 3: fix outdoor unit
1.
Place the outdoor unit on the support.
2.
Fix the foot holes of outdoor unit with bolts.
at least 3 cm above the floor
drain vent
chassis
outdoor drain joint
foot holes
foot holes
drain hose