mGuard
rs4000/rs2000
3G
I15007_en_02
Innominate Security Technologies
57
3.3.3
Connecting service contacts
The mGuard
rs4000/rs2000
3G has three digital inputs and outputs. These are configured
in the web interface, e.g., the starting and stopping of VPN, sending alarms via SMS etc..
The digital inputs and outputs are connected as follows.
Figure
3-4
Service
contacts
A
push button
or an
on/off switch
(e.g., key switch) can be connected between
service
contacts US and I.
The
service contacts O1–O3
are non-floating, continuously short-circuit-proof and supply
a maximum of 250
mA.
The switching inputs and switching outputs can be connected with signals from external de-
vices, e.g., with PLC signals. In this case, ensure the same potential as well as voltage and
current specifications are defined.
Depending on the firmware version used, the service contacts can be used for various
switching or signaling tasks.
NOTE:
Do
not
connect the voltage and ground outputs to an external source.
The plug-in screw terminal blocks of the service contacts may be removed or inserted dur-
ing operation of the mGuard.
Control switch CMD
Signal output (digital) ACK
X1 ... X3
US
I1, I2, I3
GND
O1, O2, O3
Voltage output (+)
Supply voltage
Switching input
11
... 36 V DC
Ground output (-)
Supply voltage
Short-circuit-proof
switch output,
maximum 250 mA
at 11 ... 36 V DC
Example
Example
US I2 GND O2
X2
US I3 GND O3
X3
US I1 GND O1
X1
Содержание mGuard
Страница 6: ...Innominate Security Technologies...
Страница 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Страница 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Страница 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Страница 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Страница 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Страница 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Страница 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Страница 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Страница 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...
Страница 260: ...Assigning IP addresses and setting up DHCP TFTP servers 260 Innominate Security Technologies I15007_en_02...