EAGLE
mGuard
242
Innominate Security Technologies
I15007_en_02
Mounting
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing is as follows:
•
Pull out the terminal block from the EAGLE
mGuard and wire the supply voltage lines
and signal lines.
•
Mount the EAGLE
mGuard on a grounded 35 mm DIN rail according to EN 60715.
Figure
13-5
EAGLE
mGuard: DIN rail mounting
•
Attach the top snap-on foot of the EAGLE
mGuard to the DIN rail and then press the
EAGLE
mGuard down towards the DIN rail until it engages with a click.
•
Connect the device to the local network or the local computer to be protected (LAN).
•
Via the socket for connection to the external network, establish the connection to the
external network, e.g., Internet. Connections to the remote device or network are estab-
lished via this network.
•
The front plate of the EAGLE
mGuard
housing
is
grounded
via
the
ground
connection.
Network connection
Both network interfaces of the EAGLE
mGuard
are
configured
for
connection
on
a
comput-
er.
Removal
To remove the EAGLE
mGuard from the DIN rail, insert a screwdriver horizontally in the
locking slide under the housing, pull it down – without tilting the screwdriver – and then pull
up the EAGLE
mGuard.
NOTE:
If your computer is already connected to a network, patch the EAGLE
mGuard
be-
tween the existing network connection.
Please note that configuration can only be completed via the LAN interface and that the
firewall of the EAGLE
mGuard blocks all IP data traffic from the WAN to the LAN interface.
Driver installation is not required.
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration.
When connecting to a
hub
, please note the following:
When auto negotiation is deactivated, the Auto MDIX function is also deactivated. This
means that the port of the EAGLE
mGuard
must
either
be
connected
to
the
uplink
port
of
the hub or connected to the hub using a cross-link cable.
Содержание mGuard
Страница 6: ...Innominate Security Technologies...
Страница 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Страница 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Страница 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Страница 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Страница 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Страница 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Страница 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Страница 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Страница 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...
Страница 260: ...Assigning IP addresses and setting up DHCP TFTP servers 260 Innominate Security Technologies I15007_en_02...