![INNO VIEW 5 Pro Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/inno/view-5-pro/view-5-pro_user-manual_2062296025.webp)
25
8.3 Time Lock
8.3.1 Time Lock setting
① Enter [main menu] - [System Setting] - [System Setting] - [Time Lock]
② Enter device password
③ Available to set up to 6 dates [YY/MM/DD] for Time Lock
④ Press “R” button to reset the date
⑤ Press “o” button to save after setting
⑥ Check save notification on bottom of screen, “Data save done!”
⑦ Device is locked on set dates, enter device password to unlock
8.3.2 Remark
① Passed Time Lock date is deleted
② Not allow to enter “Set Calendar” while Time Lock is working
③ Time Lock uses device password
8.4 System Setting
Parameter
Description
Buzzer
Sets the sound volume of the buzzer.
Temperature Unit
Sets the unit of temperature.
Automatic Heating
If select [On], when the fiber is placed into heat oven, which will automatically execute heat-
ing.
Dust Check
Check if there is dusk in the imaging area. Set the dust check function, OFF by default, if
select ON, duck check will be performed automaticly when turn on the splicer.
Pull Test
Set the pull test, ON by default, if select OFF, pull test will not be performed. Press RESET
manually for reset.
White LED
White LED switch.
Password Lock
Sets to enter system through password.
Reset
Restore factory setting.
Update Software
Splicer software update.
Language
Sets a language to be displayed on the screen.
Power Save Option
Sets the time of [Monitor Shut Down], time of [Splicer Shut Down] and LCD brightness.
Set Calendar
Sets the system time.
Change password
Changes the password to access some menus as [Power on Option] and [Menu Lock].
At the time of shipment from the factory, the password is set as [0000].
If you have forgotten your password after you changed another one, contact the sales agency.