4.4 Parameters for Normal Splicing Process

Parameter

Description

Template

A list of splice modes stored in the splicer database is displayed. Upon inputting the appro-

priate mode, the selected splice mode stored in database area is copied to a selected splice 

mode in user-programmable area.

Name

Title for a splice mode expressed in up to seven characters.

Note

Detailed explanation for a splice mode expressed in up to 15 characters. It is displayed at 

“Select splice mode” menu.

Align Type

Set the aligning type for the fibers. 

“Core” : fiber core alignment 

Arc adjust

Sets to adjust arc power according to the fibers’ conditions.

Pull test

If “Pull test” is set to “ON”, a pull-test is performed upon opening the windproof cover or by 

pressing the SET button after splicing.

Loss estimate

Loss estimate should be regarded as a reference. Since the loss is calculated upon the fiber 

image, there is certain difference with the real value. The estimate method is based on a 

single mode fiber and calculates at the wavelength of 1.31μm. The estimated value can be a 

valuable reference, but cannot be used as the basis of acceptance.

Minimum loss

This amount is added to the estimate splice loss originally calculated. When splicing specially 

or dissimilar fibers, a high actual splice loss may occur even with optimized arc conditions. 

To make the actual splice loss concur with the estimated splice loss, set the actual splice loss 

to minimum value (minimum loss).

Loss Limit

An error message is displayed if the estimated splice loss exceeds the selected threshold (loss 

limit).

Core angle limit

An error message is displayed if the bend angle of the two fibers spliced exceeds the selected 

threshold (Core angle limit).

Cleave angle limit

An error message is displayed if the cleave angle of either the left or right fiber ends exceed 

the selected threshold (cleave limit).

Gap position

Set the relative position of the splicing location to the center of electrodes. Splice loss may 

be improved in the case of dissimilar fiber splicing by shifting [Gap position] towards a fiber 

whose MFD is bigger than the other fiber MFD.

Gap

Set the end-face gap between the left and right fibers at the time of aligning and pre-fusion 

discharge.

Overlape

Set the overlape amount of fibers at the fiber propelling stage. Relatively small [Overlap] is 

recommended if [Preheat Arc Value] is low, while relatively large [Overlap] is recommended if 

[Preheat Arc Value] is high.

Cleaning Arc time

A cleaning arc burns out micro dust on the surface of the fiber with an arc discharge for a 

short period of time. The duration of the cleaning arc can be changed by this parameter.

Preheat Arc value

Set the pre-fuse arc power from the beginning of arc discharging to the beginning of fibers 

propelling. If “Preheat Arc Value” is set too low, axial offset may occur if cleaved angles are 

relatively poor. If “Preheat Arc Value” is set too high, fiber end faces are fused excessively and 

splice loss gets worse.

Preheat Arc time

Set the pre-fuse arc time from the beginning of arc discharging to the beginning of fibers 

propelling. Long [Preheat Arc Time] and high [Preheat Arc Value] lead to the same results.

Fuse Arc value

Set Arc power.

Fuse Arc time

Set Arc time.

Содержание VIEW 5 Pro

Страница 1: ...gn SOC Support Screen Zoom Remote Control User Manual Please read this manual before operating your fusion splicer and keep it for future reference VIEW 5 Pro MONITORING WEB SERVICE CORE ALIGNMENT FUS...

Страница 2: ...ethod Chapter 3 Basic Operation 3 1 Turn On the Splicer 3 2 Preparing the Fiber 3 3 How to Make a Splice 3 4 How to Protect the Splice Chapter 4 Splice Mode 4 1 Displaying the Active Splice 4 2 Select...

Страница 3: ...r 8 Other Functions Utilities 8 1 Data Storage 8 2 Menu Lock 8 2 System Setting 8 3 Time Lock 8 3 1 Time Lock setting 8 3 2 Remark 8 4 System Setting 8 5 System Information Chapter 9 VIEW PRO MANAGER...

Страница 4: ...e the splicer be suitable for any operating environment Dynamic operation interface and automatic splice mode provide users great convenience For more information of VIEW 5 Pro please visit our offici...

Страница 5: ...1 4 Heat Oven 5 kinds of applicable protection sleeve 20mm 30mm 40mm 50mm 60mm Heating time 20 to 900s optional Typical heating time 13 sec 45mm slim 60mm 15 sec 60mm Heating mode Various in built he...

Страница 6: ...l for fear of short circuit 6 In no case the battery cell can be dismantled 7 Do not immerse the battery into water or seawater because the battery cell cannot bear moist environment 8 Do not place or...

Страница 7: ...ndensation is present on the splicer This may result in electric shock splicer malfunction or poor splicing performance Safety glasses should always be worn during fiber preparation and splicing opera...

Страница 8: ...ing case to protect from damage and dirt Put cushion package outside the carrying case for long distance transportation Always avoid leaving the splicer in direct sunlight or expose to excessive heat...

Страница 9: ...9 2 3 Overview of External Parts Display ON OFF button Control buttons USB TYPE C Power Supply Connector Heat oven Battery...

Страница 10: ...Following is the way of installing a battery Shut off fusion splicer Press on release button at lateral drawing the battery out of the fusion splicer Place the battery into power unit slot until you...

Страница 11: ...imately 30 40mm of primary coating with an appropriate stripper 2 Clean bare fibers with pure alcohol soaked gauze or lint free tissue 3 Cleave the fiber In order to ensure the best splicing result cl...

Страница 12: ...Before continuing with splicing inspect the fibers whether they are clean and well cleaved If any defects are found please remove the fibers and prepare again Note The fibers are checked automatically...

Страница 13: ...re Open the heat oven lid Lift the left and right fiber holders on the splicer Hold the heat shrink sleeve previously placed onto the fiber Lift the spliced fibers and hold them taut Then move the hea...

Страница 14: ...14 VIEW 5 Pro move into heat oven clamp Open the heat oven lid Splicing position Heating LED indicator HEAT Button...

Страница 15: ...splice programs for common fiber combinations Therefore it is much easier to modify and further optimize the parameters for more unusual fiber combinations 4 1 Displaying the Active Splice The active...

Страница 16: ...ges during splicing is the distance between the fibers During Pre fusion the fibers are apart With the current phase changing fibers are spliced gradually Splicing Process Arc power and arc time are c...

Страница 17: ...imated splice loss exceeds the selected threshold loss limit Core angle limit An error message is displayed if the bend angle of the two fibers spliced exceeds the selected threshold Core angle limit...

Страница 18: ...use 2 is set to ON splicing operation pauses after fiber alignment is completed Ignore splice error Cleave angle Setting to OFF ignores the faults and continues to complete the splicing even if the me...

Страница 19: ...g mode These modes can be found in the database area for reference Copy the appropriate mode and paste it to the user programmable area Users can edit those parameters 6 1 Selecting Heater Mode Select...

Страница 20: ...sleeve type List of all heat modes are displayed Selected mode will be copied to a us er programmable area Name Title for a heat mode Note Title of the heat mode displayed in the upper right corner o...

Страница 21: ...wer Then turn off the splicer Remove the old electrodes I Loosen screw located on electrode cover II Take electrodes out of the electrode covers Electrodes are fixed in electrode cover 7 1 Maintenance...

Страница 22: ...e worn out during the splicing process oxide generated on the tips of electrodes should be regularly eliminated It is recommended that the electrodes should be replaced after 4500 arc discharges When...

Страница 23: ...agent 7 6 Electrode Setting This function is used to set electrode Electrodes are recommended to be replaced with new one every 4500 times splicing operation to ensure splice quality Enter into Maint...

Страница 24: ...er Splice location information It is saved with splice data Delete Splice Record Splicing results can be cleared by part or whole Enter Delete Export Splice Record and select period to search for spli...

Страница 25: ...automatically execute heat ing Dust Check Check if there is dusk in the imaging area Set the dust check function OFF by default if select ON duck check will be performed automaticly when turn on the s...

Страница 26: ...ess any key to turn on the LCD monitor Splicer Shut Down Automatically turns off the power supply of the splicer if it performs no operation for a long period of time The function serves to prevent th...

Страница 27: ...Micro SIM Nano SIM Only Nano SIM Card Support Load battery and turn on the device Detach the SIM card Tray from under the USB cover of the splicer Insert Nano SIM card to slot on the right side of ma...

Страница 28: ...Set up SIM card lock Enter the APN information manually on Network Setting If APN requires password enter it to Network setting on the splicer Splicer System menu Network Setting ICON Description GPS...

Страница 29: ...lick Bind Splice 1 2 3 4 5 6 7 9 8 Serial number IMEI number can be found on system information Manager Authority Able to delete a User and Lock the splicer remotely User Authority Only available to a...

Страница 30: ...ct the period to search splice data 5 Current device location with device information location name model etc 1 2 3 4 5 1 Period selection and data type for selected devices Marker Splice point with c...

Страница 31: ...31 More Introduction and guidance can be found in HELP under account menu Under developing...

Страница 32: ...ng arc Clean fiber thoroughly or increase Cleaning Arc Time Bubbles Bad fiber end face quality Check the cleaver Pre fuse power too low or pre fuse time too short Increase Pre fuse Power and or Pre fu...

Страница 33: ...dirt on the fiber surface Prepare the fiber stripping cleaning and cleaving again Mismatch Fibers Use an appropriate splice mode other than AUTO splice mode to re splice Non standard optical fibers AU...

Страница 34: ...Cleaning Arc time to 180ms Splice the fibers whose cores are difficult to find by the way of core alignment Splice the fibers whose cores are difficult to find by MM splice mode cladding layer alignm...

Страница 35: ...turn the splicer power off after an extended period of inactivity 7 Mismatch between Estimated splice loss and Actual splice loss The estimated loss is a calculated loss so it can be used for referen...

Страница 36: ...Products models and specifications are subject to change without prior notice The End...

Страница 37: ...nt com Please visit us on Facebook www facebook com innoinstrument Copyright 2021 INNO Instrument Inc All rights reserved E 22F 30 Songdomirae ro Yeonsu gu Incheon 21990 Republic of Korea tel 82 32 83...

Отзывы: