Installing and connecting the unit
Ingeteam
ABA2013IQM01_ - Installation and usage manual
2.
In order to mount the unit, it is necessary to install a support on the wall using three fastening elements.
After carrying out this operation, hang the unit from the support.
3.
Once it is hanging from the wall support, complete the attachment using a fastening element inserted
through the purpose-designed hole at the bottom of the station.
4.
Check that the unit is properly secured.
7.2.2. Connecting the power to the unit
Cabling requirements
The connection must meet certain requirements:
Connection specifications
Connection type
Single phase
Three phase
Number of conductors
2P + E
3P + N + E
Nominal current
16 A
up to 32 A
Conductor maximum diameter
10 mm
2
(2 x 6 mm
2
)
Wiring process
In order to connect the unit it is not necessary to open its front enclosure. A window is located at the bottom of the
unit, to access the terminal block to which to make the connection.