19
Service Facts
M952-SF-4
M952V060BD36AB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY =
2nd STAGE CAPACITY =
38,000
59,000
AIRFLOW
SETTING
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
HEATING
1ST
STAGE
LOW
ON
ON
CFM
TEMP. RISE
WATTS
600
56
55
600
56
85
600
56
120
600
56
150
600
56
185
MEDIUM LOW
OFF
ON
CFM
TEMP. RISE
WATTS
675
50
65
675
50
105
675
50
140
675
50
175
675
50
205
NORMAL **
ON
OFF
CFM
TEMP. RISE
WATTS
750
45
85
750
45
125
750
45
160
750
45
210
750
45
260
HIGH
OFF
OFF
CFM
TEMP. RISE
WATTS
850
40
115
850
40
155
850
40
205
850
40
260
850
40
320
HEATING
2ND
STAGE
LOW
ON
ON
CFM
TEMP. RISE
WATTS
900
58
125
900
58
165
900
58
220
900
58
270
900
58
315
MEDIUM LOW
OFF
ON
CFM
TEMP. RISE
WATTS
1000
52
170
1050
50
230
1050
50
295
1050
50
335
1050
50
370
NORMAL **
ON
OFF
CFM
TEMP. RISE
WATTS
1100
47
215
1150
45
285
1150
45
340
1150
45
395
1100
47
440
HIGH
OFF
OFF
CFM
TEMP. RISE
WATTS
1300
40
330
1325
39
385
1325
39
455
1250
42
465
1200
43
470
** Factory setting
M952V060BD36AB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
SW 1
SW 2
SW 3
SW 4
0.1
0.3
0.5
0.7
0.9
1.5
LOW
(350 CFM/TON)
OFF
OFF
OFF
ON
CFM
WATTS
525
45
525
70
525
100
525
135
525
160
NORMAL
(400 CFM/TON)
OFF
OFF
OFF
OFF
CFM
WATTS
600
55
600
85
600
120
600
150
600
185
HIGH
(450 CFM/TON)
OFF
OFF
ON
OFF
CFM
WATTS
675
65
675
105
625
140
675
175
675
205
2.0
LOW
(350 CFM/TON)
ON
ON
OFF
ON
CFM
WATTS
700
70
700
115
700
145
700
185
700
220
NORMAL
(400 CFM/TON)
ON
ON
OFF
OFF
CFM
WATTS
800
100
800
135
800
175
800
225
800
280
HIGH
(450 CFM/TON)
ON
ON
ON
OFF
CFM
WATTS
900
125
900
165
900
220
900
270
900
330
2.5
LOW
(350 CFM/TON)
OFF
ON
OFF
ON
CFM
WATTS
875
115
875
160
875
210
875
260
875
310
NORMAL
(400 CFM/TON)
OFF
ON
OFF
OFF
CFM
WATTS
1000
150
1000
207
1000
265
1000
320
1000
380
HIGH
(450 CFM/TON)
OFF
ON
ON
OFF
CFM
WATTS
1125
215
1125
285
1125
340
1125
395
1125
440
3
LOW
(350 CFM/TON)
ON
OFF
OFF
ON
CFM
WATTS
1050
175
1050
240
1050
305
1050
345
1050
380
NORMAL
(400 CFM/TON)
ON
OFF
OFF
OFF
CFM
WATTS
1200
240
1200
315
1200
385
1200
440
1100
410
HIGH
(450 CFM/TON)
ON
OFF
ON
OFF
CFM
WATTS
1350
330
1350
410
1350
500
1275
485
1170
450
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
Содержание M952V060BD36AB
Страница 7: ...7 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345191P01...
Страница 8: ...8 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM2 From drawing D345191P01...
Страница 9: ...9 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345192...
Страница 10: ...10 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM From drawing D345192...
Страница 37: ...37 Service Facts M952 SF 4...