12
Service Facts
M952-SF-4
GROUND
TO PIN #4
TO PIN #5
A.C. VOLTS
#3
#4
#5
Quick Check Motor Will Not Run
3. Unplug 16 wire low voltage harness from the motor.
Jumper 24 Volts A.C. to motor low voltage plug pins #12
and #15 and pins #1 and #3 which are common.
Does motor run?
NO:
Go to step #4.
YES:
Fault is in the
16 wire low voltage
harness. Repair or
replace it.
4. Is the line voltage to the motor high voltage power plug
pin #4 and pin #5 correct?
NO:
Correct line voltage fault.
YES:
Live voltage correct and
motor will not run.
Replace motor .
TO PIN #1 & #3
24 VOLT A.C.
Содержание M952V060BD36AB
Страница 7: ...7 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345191P01...
Страница 8: ...8 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM2 From drawing D345191P01...
Страница 9: ...9 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345192...
Страница 10: ...10 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM From drawing D345192...
Страница 37: ...37 Service Facts M952 SF 4...