NIRVANA OIL-FREE COMPRESSOR
X-Axis (Read Only
- The time duration is selectable from
page six. The sample rate varies, based on the selected
duration.
The graph plots a minimum of 255 readings
PAGE 6 – GRAPHING SELECTIONS
The selections for page one through five are organized
sequentially in rows. The top row has page one selections and
the bottom row has page five selections.
Variables
- include all analog inputs as well as some
calculated variables. The amount of variables will vary
depending on the compressor type and the options it has.
Duration
- selectable from the following five times
10 minutes
30 minutes
60 minutes
12 hours
24 hours
These times are fixed and cannot be changed.
MAINTENANCE FOLDER
PAGE 1 – FILTER STATUS
This page displays the status of the filters. The filter status will
either be “OK” or “Change” depending on the compressor’s
diagnostic readings. If a filter reaches the “change’ status, a
warning will be issued and the service indicator will light up
yellow to notify the user. Please note that the compressor
must be in a “Running Loaded” state to check these
maintenance items. If the compressor is not in a running state
– the status will display “Load,” unless a maintenance indicator
has been issued when the machine was running and has not
yet been reset.
The following filters are displayed:
Oil Filter
Inlet Filter
•
•
•
•
•
•
•
•
•
PAGE 2 – MAINTENANCE STATUS
This page displays the time until the unit should be serviced.
The service meter will deplete as the hours count down closer
to a service appointment. Once the counter reaches the
yellow zone, the service indicator will light up yellow. Once
the counter reaches the red zone the service indicator will
light up red and maintenance must be performed.
PAGE 3 - MAINTENANCE CONFIGURATION
This page allows the user to set the service interval and to
reset the counter after the service has been performed.
The service interval may be set to any value between 1000
and 8000 hours, but must be set in accordance with the
factory maintenance schedule. After maintenance has been
performed, the user can reset the counter by navigating to
the Reset button and pressing the enter key.
GENERAL SETTINGS FOLDER
All parameters in the general settings folder are adjustable.
PAGE 1 – LANGUAGE AND UNITS OF
MEASURE SELECTION
Language
(< >) is selectable from the following 31 selections:
•
•
•