EN
68
80448608 Rev B
Register 94: Pressure - Modbus
Register 95: Temperature - Modbus
0 = psi
1 = kPa
2 = bar
3 = kg/cm
2
0 = Degrees F
1 = Degrees C
Register 98: Compressor Type
Register 99: Service Level
0 = 37 kW / 50 hp
1 = 45 kW / 60 hp
2 = 55 kW / 75 hp
3 = 75 kW / 100 hp
4 = 90 kW
5 = 125 hp
6 = 110 kW
7 = 150 hp
8 = 132 kW
9 = 200 hp
10 = 160 kW
0 = Level 0
1 = Level 1
2 = Level 2
Registers 127, 128: Day
0 = Sunday
1 = Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6 = Saturday
7 = Daily
8 = Weekdays
9 = Weekends
Table : 2
Code
Description
1
Sensor Failure 1AVPT
2
Sensor Failure 2APT
3
Sensor Failure 3APT
4
Sensor Failure 4APT
6
Sensor Failure 5OPT
7
Sensor Failure 6OPT
8
Sensor Failure 1ATT
9
Sensor Failure 2ATT
10
Sensor Failure 3ATT
11
Sensor Failure 4ATT
12
Sensor Failure 5OTT
13
Sensor Failure 7ATT
17
Remote Sensor Failure
18
High VSD Temperature
19
Fan Motor Overload / Blower Fault
20
High 1st Stage Discharge Temp.
21
High 2nd Stage Discharge Temp.
22
High Bearing Oil Temp.
23
High I/C Air Temp.
24
2nd Stage Over Ratio
25
Remote Stop Failure
26
Remote Start Failure
27
Incorrect VSD Type
28
High Condensate Level
Code
Description
29
High Air Pressure
30
Low Bearing Oil Pressure
31
High 1st Stage Inlet Temperature
32
Emergency Stop
33
Change Inlet Filter/Inlet Restriction
34
High I/C Pressure
35
Change Oil Filter/Oil Filter Pressure Drop
36
High 2nd Stage Discharge Pressure
38
100 Hours To Service
39
Service Required
40
Alarm – Service Required
41
Auxiliary 2
42
Auxiliary 1
43
Failed Check Valve
46
Check Incoming Power
47
Invalid Calibration
48
Power Module Timeout
50
VSD Communication Failure
51
VSD Initialization Fault /Waiting for VSD Comm
52
Stop Failure
53
Check Motor Rotation
54
Negative Speed
55
Isolation Contact Open
56
Wait for Motor to Stop
MODBUS