7
Install Silver XM Control
Local enrollment option
step 1: enroll the thermostat into the bridge.
1. Disconnect the Nexia Home Bridge from the router and AC power.
2. Insert a fresh 9V battery to power the Bridge during local
enrollment.
3. Carry the Bridge over to the thermostat module. Hold the Bridge
within 6 feet (1.8 meters) of the thermostat during the following
enrollment process.
4. Press and release the
+ button on the Bridge.
5. Press
Menu on the thermostat.
6. Scroll down to
[Z-Wave Install].
7. Press
[Yes].
8. Observe the indicator lights on the Bridge. The orange Z-Wave light
will blink during enrollment. Enrollment is complete when the
orange light stops blinking and glows continuously.
step 2: reconnect the bridge to the internet.
1. Reconnect the Bridge to AC power and the router. The Bridge
will automatically update the Nexia server.
2. Return to the Nexia account setup screen to verify successful enrollment,
as indicated by a checkmark next to the name of the thermostat, a
confirmation message, and a prompt to assign a new name.
Note: Browser feedback is not immediate. The online display may take up to
1 minute to change. Be sure to allow time for the browser to update.
If you experience problems with the standard enrollment process
described above, you have the option to use local enrollment. This
involves moving the Nexia Home Bridge to within 6 feet of each device
you want to enroll. Once you’ve enrolled every device, you would then
return the Nexia Home Bridge to wherever you originally placed it. We
have listed the specific steps below.
Содержание American Standart Nexia
Страница 1: ...Nexia Home Intelligence Installation and Account Setup...
Страница 3: ...1 Introduction...
Страница 5: ...2 Be Prepared...
Страница 9: ...3 Install Silver XM Control...
Страница 19: ...4 Install Gold XV Acculink Platinum XV Control...
Страница 35: ...5 Install Acculink Platinum ZV Control...