Nokia G-240WZ-A - мощный и надежный маршрутизатор для домашней сети. На нашем сайте вы можете бесплатно скачать его инструкцию по эксплуатации на русском языке. Посетите manualshive.com и узнайте больше о возможностях этого устройства.
1
Nokia Smart Home 7368 GPON ONT - G-240WZ-A User Manual
Nokia Smart Home
7368 GPON ONT - G-240WZ-A
User Manual
Страница 1: ...1 Nokia Smart Home 7368 GPON ONT G 240WZ A User Manual Nokia Smart Home 7368 GPON ONT G 240WZ A User Manual ...
Страница 2: ...evices 7 3 4 Unknown Devices 7 3 5 Managing Rooms 8 3 6 Managing Devices 8 4 0 Managing your Z Wave Devices 9 4 1 Adding Z Wave devices 9 4 2 Removing a Z Wave devices 9 5 0 Controlling Z Wave Devices 10 5 1 Controlling On Off Plug 10 5 2 Controlling Dimmer 10 5 3 Controlling Lamp Mount 10 5 4 Controlling Door Lock 10 5 5 Controlling Siren 11 5 6 Smoke Detector 11 5 7 Motion Detector 11 5 8 Thermo...
Страница 3: ...ult 15 Appendix A Preferred device list 16 NOKIA SMART HOME ONT G 240WZ A Supported Z Wave EU Frequency Devices 17 NOKIA SMART HOME ONT G 240WZ A Supported Z Wave US Frequency Devices 18 Appendix B Technical Specification 19 Z Wave Technical information 19 Implemented Z Wave device class 19 Supported Command Class 19 Controlled Command Class 21 Association Group Info 22 Z Wave Technical and Manufa...
Страница 4: ...8 Smart Home Product Line ONT G 240WZ A is designed to primarily used as a Central Static Controller CSC in a Z Wave network The Nokia Smart Home controller allows the management of Z Wave network and Z Wave devices in the network and additionally provides high level Home Automation functionality The Nokia Smart Home controller functionality can be accessed via the WebGUI which can be opened in a ...
Страница 5: ...or all pop up 8 After RG upgrade is completed open the RG WebGUI as indicated in steps 1 to 3 9 Click the status tab and check whether running SW version is changed to latest one 2 2 Procedure to upgrade IOT image 1 Connect Ethernet port of Laptop PC to LAN Ethernet port 1 of ONT LAN port located on the rear side of ONT 2 Open any web browser e g Firefox chrome or Internet explorer in the laptop a...
Страница 6: ...ile App follow below process 1 Connect your smartphone to the Wi Fi interface of the ONT 2 Open the Nokia Smart Home App 3 Enter username and password provided by the operator in the login window 3 2 Dashboard When user logged in to the app the Dashboard screen appears On first time logging dashboard screen will be empty as shown below As no devices are paired When user starts pairing the preferre...
Страница 7: ...ocument Non preferred devices cannot be added to any rooms and cannot be part of automation An alert also will be pop up in the mobile App when a non preferred device is paired to the Z Wave network 3 4 Unknown Devices In case of unknown devices it will be listed under Unknown sections separate unsupported room will be created automatically and unknown device gets populated in that room Unknown de...
Страница 8: ...Adding a Room 1 To add a room click on the Room icon at the bottom of the page 2 Click on icon at the top of the screen to add a new room Please enter the room name under Enter Room Name section Under Choose device label user can choose device which he wants to assign to different rooms more devices can be selected by scrolling left 3 New room will be listed on the Rooms Management screen User can...
Страница 9: ...ations menu 3 The ONT goes into the pairing mode and below screen will pop up 4 Start the inclusion mode in the slave device Refer individual device documentation on how to put the smart slave device into inclusion mode 5 After successfully pairing the smart device a Done message will be displayed 6 If the paired device is a preferred device it will be shown under All Devices menu in Overview Tab ...
Страница 10: ...icon to turn the bulb ON Tap on the icon to turn the bulb OFF When an on Off switch with metering capability device is paired to ONT mobile App will show On Off icon and metering icon Metering icon will display total power consumption in Kwh 5 2 Controlling Dimmer Paired dimmer can be either ON OFF dimmed to a value using Nokia Smart Home Mobile App Tap on the icon to open a pop up window and chan...
Страница 11: ...f Motion Detector reflects motion detected event Icon color of Motion detector reflects motion not detected event 5 8 Thermostat set point On pairing a thermostat Mobile App will show 4 icons namely Heating set points cooling set point current Temperature and climate control Set points icon to set the desired temperature current temperature icon shows temperature in centigrade climate control mode...
Страница 12: ...n Switch Fan Switch will be shown in the mobile App as shown below On clicking this Fan switch icon open a pop up window with slider and user can change the speed of the fan by sliding and click OK button 5 13Power Strip Power Strip will be shown in the mobile App as shown below Based on the number of end points supported by the connected power strip mobile App will display power end points in the...
Страница 13: ...ll be shown as Dimmer 5 14Irrigation Controller Irrigation Controller will be shown in the mobile App as shown below If the irrigation controller supports multiple end points then mobile App will show that many end points as supported in the irrigation controller device If the irrigation controller supports metering then a separate end showing total power consumption in Kwh ...
Страница 14: ...ering ON OFF smart devices To create a rule click on the icon at the right side of the screen under the rules menu of the automation screen Enter the rule name User can select more than one device as a part of rule If more than one device is selected all device conditions must be met for triggering the rule 6 2 Managing Schedules From the automation screen user can create schedules for Smart Home ...
Страница 15: ... Click OK button pop up message 6 Now ONT will do factory default setting of IOT Gateway It will erase all Z Wave configuration and restart Nokia Smart Home Gateway 7 After 7 to 9 minutes IOT SW status should reach Active online online as described previously in section 2 2 Note Reset option should be used only when the primary controller is missing or inoperable Also if the missing or inoperable ...
Страница 16: ...ncluded into ONT Z Wave network Nokia Smart Home ONT supports the following device types and home control groups 1 HC1 Door Lock Keypad Lock box 2 HC4 Notification Sensor a Smoke b Door Window c Motion 3 HC6 Multi level Sensors a Air Temperature b Humidity 4 HC8 On Off Switch Power Strip 5 HC9 Light Dimmer Switch 6 HC11 Thermostat HVAC 7 HC13 Siren Note All powered device act as a repeater regardl...
Страница 17: ... 3 Everspring ST814 Multi Sensor 4 TKBHome TZ68G Plug 5 Everspring AN158 2 Plug with Meter 6 Fibaro FGSS 001 Smoke Detector 7 Vision ZM1601 Siren 8 TKBHome TZ67G Switch Dimmer 9 Danfoss Living Connect 014G0013 Wall Thermostat 108 Merten MEG5018 0000AN158 2 Range Extender1 11 Everspring AN145 2 Lamp Mount 12 Vision ZM 1702 Door Lock 1 The Range Extender is not visible in the Nokia Smart Home mobile...
Страница 18: ...sor 4 Aeon Lab Aeotec Z Wave smart switch 6 Gen 5 Plug 5 Everspring AN163 1 Plug with meter 6 Everspring EVS SF813 2 US Smoke Detector 7 Everspring EVS SE812 US Siren 8 Everspring AD126 Switch Dimmer 9 Radio Thermostat Company of America RTC CT 30 Thermostat 10 Aeon Labs DSD37 ZWUS Range Extender2 11 Everspring AN145 1 Lamp Mount 12 Yale YRD 210 ZW 619 US Door Lock 2 The Range Extender is not visi...
Страница 19: ...central static controller to control slave devices Below is the list of supported command class Class id Version Name 5E 2 Z Wave Info 56 1 CRC16 Encap 59 1 Association Group Info 5A 1 Device Reset Locally 22 1 Application Status 72 2 Manufacturer Specific 73 1 Powerlevel 85 2 Association 86 2 Version 98 1 Security Z Wave Info command class 0x5E V2 This command class will report the information ab...
Страница 20: ...CRC16 encapsulation supported by Nokia ONT Manufacturer specific command class 0x72 V2 Manufacturer specific command class is used to identify the manufacturer and device type of a device Power Level command class 0x73 V1 Power level command class is used to check the connection quality between two Z Wave devices Association command class 0x85 V2 Association command class is used to configure end ...
Страница 21: ...ates as a central static controller any Basic SET and GET command received by the ONT from smart device will be ignored by the controller Controlled Command Class Below are command classes controlled by ONT Name Version Z Wave Info 2 CRC16 Encap 1 Association Group Info 1 Device Reset Locally 1 Manufacturer Specific 2 Association 2 Version 2 Security 1 Basic 1 Firmware Update 2 Configuration 2 Bat...
Страница 22: ...fier 01 called life line association group Association will be triggered when devices are added into the network Association Info Value Association Group 1 Association Group Name Lifeline Association Group Info Profile General Lifeline Association Group Command List 5A 01 Association Group Max No of node 1 Z Wave Technical and Manufacturer details Z Wave Value Z Wave Frequency 908 42 MHz US 868 42...
Страница 23: ...ing Flag TRUE Routing Node TRUE Optional Flag FALSE Secure Node TRUE Z Wave Plus Node TRUE Association Group 1 Association Group Name Life Line Z Wave Library ControllerStaticLib Protocol Version Z Wave version ZDK 4 5x and ZDK 6 0x Z Wave Device Chip ZW0500 Protocol Version 4 33 Application Version 4 33 ...
Страница 24: ...ork information from one controller to another replication is used during Learn Mode to copy the primary controller s Z Wave network information to the secondary controller s routing table Learn Mode Learn Mode is the state in which a slave or controller device can be added to an already existing Z Wave network Lifeline Lifeline is used in conjunction with both the Association Command Class and th...