background image

INSTALLATION

NSTRUCTIONS

WARRANTY INFORMATION

©

 

2016 

Enerwave Home Automation ● 

WWW.

ENERWAVEAUTOMATION

.COM

 ● CA, USA

Model: 

ZW15RM-P

LUS

Wireless Home Automation Control Device 

Interchangeable Face Cover

 

In-wall

 

Smart Meter TR Duplex Receptacle

020

9

1600

50

-01

INSTALLING

 Z-WAVE

 RECEPTACLE

S

LOCATIONS

Installation of Z-Wave devices instantly increases the functionality, efficiency, and value of your home. The more devices you install, the more efficient your house will be. The most effective 

locations to install Z-Wave devices are in the Living Room, Bedrooms, Kitchens, Family Rooms, Guest Rooms, and Entertainment Rooms.
This device complies with the Z-Wave standard of open-air, line of sight transmission distances of 100 feet. Actual performance in a home depends  on the numbers of walls between the remote 

controller and the destination device, the type of construction and the number of Z-Wave enabled devices installed in the control network. Z-Wave devices act as signal repeaters ONLY after 

they are "Included" on the network.

If you have trouble identifying the wires, 

STOP

 and consult with an electrician.

DO NOT REVERSE 

ANY 

WIRES.

 

DOING SO WILL VOID YOUR WARRANTY AND 

THE 

RECEPTACLE 

WILL SHORT CIRCUIT.

Step 1.

 Identify all your wires

.

 Label the wires or draw a diagram of existing wires.

Step 2. 

Insert wires into the terminal holes on the back, then tighten the terminal screws.

Connect the BLACK wire to the HOT terminal (brass screw).

Connect the WHITE wire to the NEUTRAL terminal (silver screw).

Connect the GREEN or BARE wire to the GROUND terminal (green screw). 

REQUIREMENTS

Z-Wave devices requires a connection to a compatible hub. Once the device is 

properly added to the 

H

ub, it can be managed and customized to your needs. 

Please visit www.enerwaveautomation.com for a list of compatible hubs

.

This device is warranted to be free of material and workmanship defects for 2 years from the date of 

purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty 

claim. ALL claims must be verified and approved by 

Enerwave

, Inc. Warranties from other 

Enerwave

 

products may vary. This warranty is nontransferable and does not cover normal wear and tear or any 

malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper 

installation.  To the fullest extent permitted by the applicable state law, 

Enerwave

 shall not be liable to the 

purchaser or end user customer of 

Enerwave

 products for direct, indirect, incidental, or consequential 

damages even if 

Enerwave

  has been advised of the possibility of such damages. 

Enerwave

’ total liability 

under this or any other warranty, express or implied, is limited to repair, replacement or refund.  Repair, 

replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

DESCRIPTION

The 

ZW

15R

M-Plus 

is a technologically advanced Tamper Resistant Duplex 

Receptacle. The top receptacle is "always ON" and the bottom receptacle is Z-Wave 

controlled. For the advanced users, the functions are programmable for setting scenes, 

associations and scheduling events.

FEATURES

Replaces standard 120VAC receptacles

Wireless Z-Wave technology creates a mesh network for command and control

interoperability with other Z-Wave compliant controllers and devices

Manual and remote on/off control of any connected load

Tamper-resistant (TR) receptacles keep you and your family safe

Reduce energy consumption and enjoy wireless home automation 

with Smart

Meter monitoring

Over Current and Short Circuit protection up to 15A 

SPECIFICATIONS

Voltage.............................................................................................120VAC, 60Hz

Incandescent................................................................................................1000W

Ballast.........................................................................................................1200VA

Resistive..............................................................................................1800W(15A)

Motor............................................................................................................ 1/2 HP

Z-Wave Frequency.............................................................................. 908.42 MHz

Operating Temperature........................................................................... 32-104° F

FCC  COMPLIANCE STATEMENT

FCC Grant of Equipment Authorizations of this device and transmitters installed in this device can be found at FCC website by entering the FCC ID number on the device.

Caution:

 Changes or modifications not expressly approved by the part responsible for compliance could void the user’s right to operate the equipment.  

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation of the device. 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help. 

WARNING

Turn the POWER OFF at the circuit breaker before installing the 

Receptacle

Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician perform

s

 this installation. Make sure to turn off the circuit breaker or fuse(s) 

and make sure power is off before wiring the device.

 Exercise extreme caution when using Z-Wave devices to control appliances. Operation of the Z-Wave device may be in a different room than the controlled appliance so an unintentional activation may occur if the wrong button on 

the remote is pressed. Z-Wave devices can be automatically powered on by programmed events. Unattended or unintentional operation could result in hazardous conditions. Z-Wave enabled devices should never be used to supply power to, control

,

 or monitor medical and/or life 

support equipment. 

Use copper wires only.

NEW

 Z-WAVE 500 SERIES

 FEATURES

50% improvement in battery life

67% improvement in range

250% more bandwidth

Three RF channels for improved noise immunity and higher bandwidth

New Plug-n-Play Network-wide Inclusion feature

Improved self-healing and fault tolerance with Explorer Frame feature

Standardized method for Over the Air firmware updates (OTA)

Improved product information capture for product certification database

Fully backward compatible

SMART METERING

The ZW

15RM-PLUS

 

Plug-in 

Smart Meter Module enables you to measure the 

energy usage of your 

devices.

 When added to a Z-Wave network, the Smart Meter 

Module reports real time data to your 

Hub

 or controller. It can also display actual 

consumption (in W

atts

) and the accumulated power used (in kWh) in the user 

interface of the 

Hub

. Please 

follow the instructions on the manual(s) associated 

with the Hub for configuration.

Отзывы: