Intégration Guide_iUC150&iUC180
67/70
Copyright © 2012 Ingenico
900009816 R11 000 01/1223
All rights reserved
10 STANDARDS
10.1 IUC 150 ELECTRICAL CONSUMPTIONS
•
Average consumptions device waiting for host solicitation (5 VDC input.):
- Less than 50 mA
Value measured for Power supply 5V at 25°C
•
Maximum average external supply current (5 VDC input.):
- Less than 500 mA
Value measured for Power supply 5V at 25°C
•
Maximum consumption in stand-by mode (5 VDC input.):
- Less than 50µA
Value measured for Power supply 5V at 25°C
10.2 IUC 180 ELECTRICAL CONSUMPTIONS
•
Average consumptions device waiting for host solicitation (12 VDC input.):
- Less than 120 mA
Value measured for Power supply 5V at 25°C
•
Maximum average external supply current (12 VDC input.):
- Less than 2500 mA
Value measured for Power supply 5V at 25°C
•
Maximum consumption in stand-by mode (12 VDC input.):
- Less than 400 µA
Value measured for Power supply 5V at 25°C
10.3 TEMPERATURE AND HUMIDITY
•
Operating & Storage conditions :
o
Relative humidity: 5% to 85% non-condensing.
o
External temperature range: -20 °C to 65 °C.
10.4 ENVIRONMENTAL SPECIFICATION CONTINUED
•
Operating conditions :
o
Front face shock resistance: IK10
o
Vibrations resistance: 5-9Hz, 6.2mm; 9-200Hz, 1g; 200-500 Hz, 1.5g;
10ct/mn, 10 Cycles
o
Bumps resistant: 6ms, 25g, 500 cycles each direction
•
Natural events:
o
Water and dust resistant IP64 for iUC180 and iUC150 (outside the
kiosk).