Intégration Guide_iUC150&iUC180
14/70
Copyright © 2012 Ingenico
900009816 R11 000 01/1223
All rights reserved
1.3.1.2.2 USB device
The IUC180 contactless reader unit can be connected by type B USB.
1.3.1.2.3 USB host
The iUC180 contactless reader unit can drive 4 USB accessories. The connector is
standard type A.
The power available is limited to 1.2A Max dispatched between the 4 USB.
1.3.1.2.4 Wake-up mechanism
iUC180 is designed to save power thanks to a “stand-by mode”.
If the stand-by mode is used, use Wake-up mechanism:
- with button connected on jack (optional)
- with Pin 2 of COM0 link & COM2 link
- by pressing the green key on the maintenance keyboard.
Wake-up pin state
Hz (high impedance)
Stand-by authorized
Drive to “0”
Wake-up / Stand-by unauthorized
The Wake-up pin is drive to “0” by the one asking the wake-up.
It could be driven by iUP250, iUR250 or any devices designed to be compliant (Host
device…).
Contactless
Reader IUC180
IUC180
COM0 & 2
1 – GND
2 – Wake-up
3
4
5
6
HZ => Stand-by
« 0 » => Wake-up
USB
Any devices design to
be compliant.
HZ => Stand-by